Description
The Embraco FF8.5HBK is a hermetic reciprocating compressor designed for R134a refrigeration systems running in the LBP/MBP envelope. It’s a tidy, trade-friendly replacement for light commercial gear like display fridges, merchandisers and small coolrooms—stable in Aussie heat and built for dependable pull-down.
Features & Benefits
- R134a LBP–MBP envelope — suited to common cabinet and small coolroom duties when matched correctly, helping hold tighter case temps.
- 220–240V, 50Hz single-phase — straightforward fit on Australian mains with less messing around on site.
- 7.95 cm³ displacement (FF series) — a proven size for light commercial loads where efficiency matters.
- RSIR/CSIR motor platform — compatible with typical relay/overload and (where specified) start components for repeatable starts.
- Factory POE (ester) oil charge (ISO 22) — ready to install; keep it clean and dry for long service life.
- Fan-cooled shell — helps manage compressor temps in tight machinery spaces and hot plant rooms.
Who It’s For
Best suited to licensed refrigeration mechanics and HVAC-R techs doing like-for-like replacements on R134a systems (often capillary tube cabinets and small commercial setups). If the job is “get the cabinet cold again, properly, and keep it cold”, this model is a solid pick when the sizing and duty match.
Why This Compressor Matters
In the real world, call-backs usually come from the same culprits: tired start gear, moisture left in the system, or poor airflow through the condenser compartment. The FF8.5HBK gives you a reliable base—then your commissioning does the rest. Replace worn start components, change the drier, pull a proper vacuum, and you’ll typically see cleaner starts and steadier cabinet temps.
How to Use / Install
- Confirm the match: refrigerant (R134a), duty (LBP/MBP), electrical (240V), and application (cabinet/coolroom).
- Recover refrigerant safely using approved equipment and follow site isolation/lockout procedures.
- Replace the filter drier and inspect capillary/TXV suitability (don’t assume it’ll “just work” if the old compressor was wrong).
- Braze with nitrogen purge to keep scale out of the system.
- Pressure test, then evacuate with a micron gauge (aim <500 microns plus a rise test).
- Charge by weight, then verify operation (superheat, airflow, condenser condition, and current draw).
Need a refresher on vacuum best practice? See our HVAC News guides: micron gauge vacuum measurements and vacuum pump setup.
Limitations & Safety Notes
- Licensed trade installation only (refrigerant handling + electrical work).
- R134a only — do not use on R600a/isobutane systems or any other refrigerant unless the system is designed for it.
- POE oil is hygroscopic — keep shipping plugs in place until install, minimise exposure time, and always evacuate properly.
- Airflow is non-negotiable — blocked condenser compartments cook windings and oil. Fix airflow before you blame the compressor.
What’s Included
- 1 × Embraco FF8.5HBK compressor (factory oil charge)
- Shipping/service plugs and terminal cover (as supplied)
Specs
| Attribute | Details |
|---|---|
| Model / Code | FF8.5HBK (FF series) |
| Refrigerant | R134a |
| Application | LBP / MBP (light commercial refrigeration) |
| Supply | 220–240 V, 50 Hz, 1-phase |
| Motor / Start | RSIR / CSIR |
| Displacement | 7.95 cm³ |
| Cooling | Fan-cooled shell |
| Oil Type / Charge | POE (ester) ISO 22 / ~280 mL (factory) |
| Approx. Weight | ~10.8 kg |
| Typical Capacity (R134a) | ~0.66 kW at HBP (EN12900 conditions) |
Shipping & Returns
See Shipping & Returns for delivery timeframes and the returns process. Keep packaging until commissioning is complete.
Why Buy From HVAC Shop
- Australian owned & operated HVAC-R specialist store
- Fast shipping options (metro + regional)
- Local support via Contact Us
- Secure checkout with major payment methods
- Learn more on our About Us page
FAQs
Is FF8.5HBK suitable for R600a?
No — this model is specified for R134a. Use an R600a-approved compressor for isobutane systems.
Do I need to replace the relay/overload when changing the compressor?
Strongly recommended. RSIR/CSIR units rely on healthy start gear for clean starts and fewer nuisance trips.
What oil should I use?
Factory-charged with POE (ISO 22). If top-up is required, use an OEM-approved equivalent and keep moisture out.
Capillary or TXV?
Often capillary tube on small cabinets. Always verify sizing when replacing unlike-for-like compressors.
Related Products
- Relay & Overload Combo — cheap insurance for smooth starts after a change-out.
- Start Capacitors — handy when the original is weak or out of spec.
- Refrigeration POE Oils — choose the OEM-specified grade and keep it sealed.
-
Shop Refrigeration Tools & Parts
Helpful Links
- Refrigeration tools & parts (browse driers, leak detection, service essentials)
- Vacuum pumps (faster pull-downs for cleaner installs)
- Micron gauge guide (hit your vacuum target and pass a rise test)
- Vacuum pump setup guide (best-practice hook-up and workflow)