Description
The Embraco Aspera NEU6210Z is a fully hermetic R134a HBP compressor that keeps reach-ins, merchandisers and beverage coolers ticking along with no dramas. It’s a tidy 220–240 V, 50 Hz unit with high starting torque (CSCR) so you’re off the ladder faster and back to the next job.
Key Features & Trade Benefits
- R134a HBP application — ideal for display fridges and reach-ins; reliable pull-down without overworking the system.
- High start torque (CSCR) — kicks over cleanly on tight heads and warm shops, reducing nuisance call-backs.
- Rated capacity ~1085 W at 5 °C evap / 50 °C cond — proven cooling where merchandisers actually run.
- Efficient at real-world temps — up to ~3.3 W/W at mid loads; helps keep energy costs in check.
- Factory oil charge (POE ISO 22, ~350 ml) — crack the drier, evacuate, charge, and you’re away.
- Compact “UNI” base — straightforward mounting with standard rubber feet; quick swap-outs.
- Serviceable tube stubs — 8.1 mm suction, 6.45 mm discharge/process for clean brazing.
Why This Product Matters
Real story: a sparky mate in Newcastle rang about a drinks merchandiser losing temp every arvo. We dropped in a NEU6210Z, pulled to sub-500 microns, weighed in the charge, and the cabinet was back at setpoint before smoko. Fair dinkum, that’s the difference a correctly sized HBP R134a can make on a hot day.
For broader refrigeration gear and spares, you can browse our Refrigeration collection for compatible tools and components that keep the whole system she’ll be right.
Pro Tip
Fit a fresh liquid line drier and pressure-test with nitrogen before evacuation. Log your vacuum with a micron gauge and isolate for a decay test. It’s a small step that saves a stack of call-backs on cap tube systems. No worries.
Compatibility & System Info
- Refrigerant: R134a
- Application: HBP (typical evap range −5 °C to +10 °C)
- Systems: Capillary tube or expansion valve; display fridges, reach-ins, merchandisers
- Electrical: 220–240 V, 50 Hz, single-phase (CSCR start)
Local note: In Sydney humidity and Brisbane heat, verify condenser cleanliness and airflow, and confirm fan direction after a swap to keep head pressure in the sweet spot.
What’s Included
- Embraco NEU6210Z hermetic compressor (factory-charged with ~350 ml POE ISO 22)
- Integrated overload protection
- CSCR start configuration (use specified start capacitor; verify box contents on delivery)
- Installation leaflet (where supplied)
Specifications
Item | Spec |
---|---|
Model / Engineering code | NEU6210Z / 268HA92 |
Power supply | 220–240 V, 50 Hz, 1-ph |
Application | HBP (R134a) |
Cooling capacity (rated) | ~1085 W @ +5 °C evap / +50 °C cond (EN12900) |
Efficiency (rated) | ~2.38 W/W |
Displacement | 12.11 cm³ |
Motor type / start | CSCR (High start torque) |
Start capacitor (typ.) | 64–77 µF / 330 V |
Run current (RLA) | ~3.1 A (HBP, 50 Hz) |
Locked-rotor amps (LRA) | ~18.5 A (50 Hz) |
Oil / charge | POE (ester) ISO 22 / ~350 ml |
Weight | ~10.5–11 kg |
Suction stub | Ø 8.1 mm (slanted 42°) |
Discharge / process stubs | Ø 6.45 mm |
Base | UNI (standard mounting) |
Warranty & Returns
Backed by manufacturer warranty. HVAC Shop supports returns per our Shipping & Returns policy. Standard Australian consumer guarantees apply.
FAQs
Is the NEU6210Z a direct drop-in for my old R134a merchandiser?
Often yes if the duty matches. Check footprint (UNI base), tube sizes (8.1 mm suction, 6.45 mm discharge/process), and capacity at your design temps.
Do I need a start capacitor?
Yes. The NEU6210Z is CSCR. Use a 64–77 µF / 330 V start capacitor with the correct relay/overload per Embraco specs.
What oil is inside and can I top it up?
Factory-filled with POE ISO 22 (~350 ml). If you must add oil, use the same viscosity and type. Avoid mineral oil with R134a POE systems.
Can I use hydrocarbons (R600a) instead?
No. This model is specified for R134a HBP applications. Always follow Australian standards and the current refrigerant handling codes for safety and compliance.
Related Products
- Bradley NR1000 High-Pressure Nitrogen Regulator — pressure test and purge before every evac.
- Vacuum Pumps Collection — pick a pump that reliably hits sub-500 microns.
- Embraco NEU6215GK — nearby Embraco spec if you need a different duty.
- Hilmor Nitrogen Purge Tool — keep brazes oxide-free on cap tube systems.