This Brivis Gas Heater Pilot Injector Tradie Pack provides ten genuine 0.46mm EF15T Natural Gas (NG) injectors (Honeywell 390686-4), essential for keeping Brivis gas heaters running reliably through the Aussie winter. It's a lifesaver for busy HVAC techs, gas fitters, and maintenance teams needing to service multiple units or have spares on hand.
Nothing's worse than a pilot light dropping out on a cold winter's night, so having a pack of these genuine parts means you can get the heat back on fast without waiting for a reorder.
Best For
- Licensed Gas Fitters
- HVAC Service & Maintenance Teams
- Brivis Gas Heater Specialists
Compatibility
This pilot injector pack is designed for Brivis gas heaters that utilise the 0.46mm EF15T Natural Gas (NG) Honeywell 390686-4 pilot injector. It's crucial for maintaining correct gas flow and ignition performance in compatible models. If you're running a different model, check fittings and specs before ordering.
Features
- Tradie Pack Quantity: Includes 10 individual pilot injectors, great for stocking the work van.
- Genuine Brivis/Honeywell Part: Ensures direct fit and reliable performance.
- 0.46mm Orifice: Precisely sized for correct gas flow on specified Brivis heaters.
- Natural Gas (NG) Specific: Optimised for natural gas systems.
- EF15T Type: Matches specific pilot assembly designs for easy replacement.
Technical Specifications
| Specification | Detail |
|---|---|
| Injector Orifice Size | 0.46mm |
| Gas Type | Natural Gas (NG) |
| Injector Type | EF15T |
| Manufacturer Part No. | Honeywell 390686-4 |
| Pack Quantity | 10 injectors |
| Weight (Tradie Pack) | 0.50 KGS |
| Warranty | 12 Months |
What's in the Box
- 10 x Brivis Gas Heater Injector Pilot (0.46mm, EF15T, Natural Gas, Honeywell 390686-4)
Using It on the Job
- Isolate Services: Always turn off and tag out the gas and electrical supply to the Brivis heater before starting any work.
- Access Pilot Assembly: Refer to the Brivis heater's service manual to safely access the pilot assembly where the injector is located.
- Remove Old Injector: Carefully unthread and remove the existing pilot injector, noting its precise location and orientation.
- Install New Injector: Thread the new 0.46mm NG injector into place, ensuring it's snug but not overtightened to avoid damaging threads.
- Reassemble & Leak Check: Put the pilot assembly and heater panels back together. Conduct a thorough gas leak check using an approved leak detection solution.
- Test Operation: Restore gas and electrical supply. Test the heater's ignition sequence and verify a stable, clear blue pilot flame.
Limitations & Safety Notes
- Licensed Installation: All gas and electrical items must be installed by a currently licensed installer in accordance with Australian standards.
- Natural Gas Only: This injector is for Natural Gas (NG) systems only. Do not use with LPG or other gas types.
- Match Specifications: Verify that the 0.46mm EF15T specification matches the requirements of the specific Brivis heater model you are servicing.
- Manufacturer Guidelines: Always follow the specific installation and safety guidelines provided in the Brivis heater's service manual.
- Post-Installation Checks: Conduct thorough gas leak detection and operational checks after any replacement of gas components.
Tradie Pro Tip
Keep a few of these 0.46mm pilot injectors in your van. They're small, easy to misplace, and a common culprit for nuisance pilot outages. Swapping one out can save you a much bigger job and a repeat call-out.
Pair With