Testo H2S Retrofit Sensor

TestoSKU: 0554 2350

Price:
Sale price$6,580.20

incl. GST

Get a Fast Quote

🛠️ Need the Right HVAC Tool for the Job?

Whether you're quoting a bulk order or chasing hard-to-find tools, we’re here to help.

Get a fast, personalised quote—no pressure, no spam!
Fill out the form below and we’ll get back to you ASAP.

📩 Request a Quote

Description

This Testo H2S retrofit sensor lets you add hydrogen sulphide measurement to your compatible flue gas analyser. It's a handy piece of gear for anyone needing to monitor H2S levels in combustion processes or industrial emissions, giving you critical data right there on your Testo 350. You know how important accurate flue gas readings are for tuning boilers and ensuring compliance, especially when dealing with sulphur compounds; this sensor helps you nail those numbers.

Best For

  • HVAC service technicians performing combustion analysis
  • Industrial maintenance teams monitoring emissions
  • Compliance testing for H2S in flue gas
  • Anyone with a compatible Testo 350 analyser looking to expand measurement capabilities

Compatibility

This H2S retrofit sensor is designed specifically for the Testo 350 series of portable emission analysers. You'll find it compatible with models like the Testo 350 Portable emission analyzer (0632 3510) and the Testo 350 Process Kit (400563 3511). If you're running a different model, check fittings and specs before ordering.

Features

  • H2S Measurement: Adds hydrogen sulphide (H2S) measurement to your compatible Testo flue gas analyser.
  • Precalibrated Sensor: Comes ready to go, saving you calibration time on site.
  • Easy Installation: Designed for simple, self-installation into the analyser.
  • Expands Analyser Capability: Activates the H2S measurement parameter within your Testo 350.
  • Robust Design: Features a durable plastic housing, built for the rough and tumble of site work.

Technical Specifications

Parameter Value
Measuring Range 0 to 200 ppm H2S
Resolution 0.1 ppm H2S
Weight 18 g (0.64 oz.)
Dimensions (LxWxH) 40 x 30 x 30 mm (2 x 1 x 1 in.)
Housing Material Plastic
Product Colour Grey; Blue

What's in the Box

  • 1 x Testo H2S Retrofit Sensor (0554 2350)

Using It on the Job

  1. Power Down Analyser: Always switch off your Testo 350 analyser and disconnect it from power before opening any compartments.
  2. Access Sensor Bay: Carefully open the sensor compartment on your Testo 350 according to the analyser's manual.
  3. Insert New Sensor: Gently slide the precalibrated H2S retrofit sensor into its designated slot. Ensure it's seated firmly and correctly.
  4. Close Analyser: Securely close the sensor compartment and re-latch any covers.
  5. Power Up & Test: Power on your Testo 350 and navigate to the measurement parameters. Confirm that the H2S option is now active and displaying readings.
  6. Function Check: Perform a zeroing or fresh air purge as per your analyser’s guidelines to ensure accurate baseline readings before performing any flue gas analysis.

Limitations & Safety Notes

  • This sensor is specifically designed for use with compatible Testo 350 series flue gas analysers. It will not function as a standalone H2S detector.
  • H2S (Hydrogen Sulphide) is a highly toxic gas. Always use appropriate personal protective equipment (PPE) and follow Safe Work Australia guidelines when working in environments where H2S may be present.
  • Always refer to your Testo 350 analyser's operating manual for specific instructions on sensor installation and general use.
  • Ensure the analyser is powered off and disconnected from any probes or power sources before attempting sensor installation.

Tradie Pro Tip

When you're doing a lot of flue gas analysis, especially in industrial settings, having a spare set of common sensors on hand can save you a heap of downtime. Swapping a precalibrated sensor like this one is quick and keeps you moving without waiting for a service call.

Pair With

Team this H2S retrofit sensor with your Testo 350 Portable Emission Analyser and a range of flue gas probes to ensure you have a comprehensive kit for all your combustion analysis needs. Consider a robust carry case for protecting your valuable Testo gear on site.

Common Questions for Testo H2S Retrofit Sensor

This H2S retrofit sensor is compatible with the Testo 350 Portable Emission Analyser (0632 3510) and the Testo 350 Process Kit (400563 3511). It's designed specifically for the Testo 350 series to expand its measurement capabilities.

No, the Testo H2S retrofit sensor (0554 2350) comes precalibrated from the factory. You can simply insert it into your compatible Testo 350 analyser without needing immediate calibration.

The H2S retrofit sensor has a measurement range of 0 to 200 ppm (parts per million) for hydrogen sulphide. It provides a resolution of 0.1 ppm for precise readings in flue gas.