This genuine Seeley 12V Super Stealth drain valve is crucial for keeping evaporative coolers running right, preventing stagnant water and ensuring optimal performance. It's a direct replacement for various Seeley and Braemar models, helping maintain efficiency through long Australian summers.

A faulty drain valve can lead to water pooling, algae growth, and bigger headaches down the line, so getting this sorted quickly is always a good call for system longevity and hygiene.

Best For

  • Evaporative Cooler Service Technicians
  • HVAC Apprentices
  • Competent DIY Homeowners Maintaining Seeley or Braemar Units

Compatibility

This Seeley 12V Super Stealth drain valve is primarily designed for use with Braemar LCQI and LPI evaporative cooler units. It's also a common replacement for various Seeley LCI and LPI models. If you're running a different unit, check your existing drain valve's voltage and part number against Seeley PN 116389 before ordering.

Features

  • Genuine Seeley brand drain valve for reliable performance.
  • Designed for 12V DC operation, standard for many evaporative cooler controls.
  • Direct fit replacement for Braemar LCQI and LPI evaporative cooler units.
  • Original Manufacturer's Part Number: Seeley PN 116389.

Technical Specifications

Specification Detail
Voltage 12V DC
Manufacturer PN 116389
HVAC Shop SKU SY116389

What's in the Box

  • One (1) Seeley Drain Valve 12V Super Stealth (SY116389)

Using It on the Job

  1. Isolate power to the evaporative cooler at the mains or switchboard. Lock out the breaker if possible to prevent accidental re-energisation.
  2. Drain the existing water from the cooler's tank, typically through the old drain valve or a manual drain point.
  3. Carefully disconnect the wiring and plumbing from the old drain valve, noting its orientation and connections.
  4. Install the new Seeley 12V Super Stealth drain valve, ensuring all O-rings and seals are correctly seated for a watertight fit.
  5. Reconnect the low-voltage wiring to the valve, matching polarity if specified.
  6. Restore power to the cooler and test the unit's drain cycle for proper operation, checking thoroughly for any leaks before leaving the site.

Limitations & Safety Notes

  • Always ensure power is isolated before any installation or maintenance work on evaporative coolers.
  • This drain valve is only for use with compatible Seeley and Braemar 12V evaporative cooler systems. Do not attempt to use it with higher voltage circuits.
  • Refer to the cooler's specific manufacturer manual for detailed installation procedures and wiring diagrams.
  • Thoroughly check for leaks after installation to prevent water damage to roofing or ceilings.

Tradie Pro Tip

Before you disconnect the old valve, snap a quick photo of the wiring and plumbing connections. It saves a lot of head-scratching when you're hooking up the new one, especially if you're working on a dusty rooftop.

Pair With

Pair with new evaporative cooler filter pads and a quality float valve to give the whole system a solid refresh and ensure consistent water levels.

Common Questions for Seeley Drain Valve 12V Super Stealth LCI & LPI

This 12V Super Stealth drain valve is a direct replacement for Braemar LCQI and LPI evaporative cooler units, as well as various Seeley LCI and LPI models. Always double-check your cooler's manual for part numbers if you're unsure of compatibility.

The Seeley SY116389 drain valve is designed to operate on a 12V DC power supply. This voltage is standard for the control circuits in many evaporative cooler systems.

Yes, for competent DIY owners with basic electrical and plumbing knowledge, replacement is straightforward. Remember to always isolate power at the mains and confirm water supply is off before starting any work to ensure safety.