Description
This Brivis N-G2B+ control board is a direct replacement part for keeping ducted gas heaters running smoothly, crucial for those chilly Australian winters. It includes the igniter, saving you time and hassle on the job.
Anyone who's been stuck fault-finding a temperamental ducted heater knows the relief of slotting in a new, reliable board to get things firing again.
Best For
HVAC technicians, gasfitters, and maintenance teams working on Brivis ducted gas heating systems.
Compatibility
This board is specifically designed for Brivis N-G2B+ ducted gas heaters. It also replaces older Brivis NG2 and N-G2A+ models, making it a versatile spare to have on hand. The Brivis part numbers for this component are 80080223, B080223, and 80080246.
If you're running a different model, check fittings and specs before ordering.
Features
- Genuine Brivis N-G2B+ control board for exact fit and function.
- Direct replacement for Brivis NG2 and N-G2A+ boards.
- Integrated igniter, ensuring spark generation for burner ignition.
- Maintains reliable control over critical heating cycles and safety functions.
What's in the Box
- 1x Brivis N-G2B+ Control Board
- 1x Integrated Igniter
Using It on the Job
- Before starting, always isolate power to the ducted gas heater at the main switchboard and perform a lockout procedure.
- Shut off the gas supply to the appliance at the isolation valve.
- Document wiring connections or take photos before disconnecting the old board.
- Carefully remove the faulty control board and install the new Brivis N-G2B+ board, ensuring all connections are secure and correct.
- Restore gas and electrical supply, then test the heater through a full cycle to confirm proper operation and check for any fault codes.
- Clean the area and ensure all access panels are correctly re-secured after the repair.
Limitations & Safety Notes
- Installation and servicing of gas appliances must be carried out by a licensed gas fitter in accordance with Australian standards.
- Always ensure power is isolated and locked out before attempting any work on electrical components.
- Confirm compatibility with your specific Brivis ducted gas heater model before installation.
- Do not bypass any safety devices or controls on the board or appliance.
Tradie Pro Tip
When swapping out these boards, a common mistake is rushing the wiring. Take your time, double-check every connection against the wiring diagram, and give all terminals a gentle tug before powering up. It saves a headache later.
Pair With
Pair with a digital multimeter for fault-finding electrical issues and a quality gas pressure test kit to verify burner pressure after repair. HVAC Shop also stocks a range of Brivis wall controllers and pressure switches.