Bonaire Vulcan Gas Heater Fan Assembly 315W

BonaireSKU: CTSPS5430805SP

Price:
Sale price$600.12

Get a Fast Quote

🛠️ Need the Right HVAC Tool for the Job?

Whether you're quoting a bulk order or chasing hard-to-find tools, we’re here to help.

Get a fast, personalised quote—no pressure, no spam!
Fill out the form below and we’ll get back to you ASAP.

📩 Request a Quote

Description

This Bonaire Vulcan Gas Heater Fan Assembly is a direct replacement part designed to get your heating system back up and running. It includes the 315-watt motor, mounting plate, and capacitor, making the swap-out straightforward for qualified technicians.

Anyone who's swapped out one of these knows a smooth-running fan is critical for efficient heat distribution, especially during a chilly Aussie winter. This assembly helps ensure your Bonaire gas heater keeps pushing warm air throughout the home or workspace.

Best For

  • HVAC Service Technicians
  • Gas Appliance Repairers
  • Maintenance Teams
  • Competent DIY owners undertaking specific repairs (with electrical safety knowledge)

Compatibility

This fan assembly (Bonaire PN 5430805SP) is specifically suited for newer style Bonaire Gas Heaters. Always verify the part number and wattage against your existing unit or the manufacturer's specifications.

If you're running a different model, check fittings and specs before ordering.

Features

  • Direct replacement Bonaire Fan Assembly Kit
  • Includes a robust 315 Wattage Motor
  • Comes pre-wired with the correct capacitor for plug-and-play installation
  • Supplied with the necessary mounting plate for easier fitting
  • Genuine Bonaire Part Number 5430805SP for guaranteed fit and function

Technical Specifications

Specification Detail
Motor Wattage 315W
Part Number 5430805SP

What's in the Box

  • Bonaire Fan Assembly with 315W Motor
  • Mounting Plate
  • Capacitor (pre-connected)

Using It on the Job

  1. Isolate Power: Always begin by switching off and locking out the main power supply to the gas heater at the circuit breaker.
  2. Access Panel Removal: Carefully remove the heater's access panels to expose the existing fan assembly.
  3. Disconnect Wiring: Document and then disconnect all electrical connections from the old fan motor and capacitor. Pay attention to earth connections.
  4. Remove Old Assembly: Unbolt and remove the faulty fan assembly, noting its orientation for the new unit.
  5. Install New Assembly: Position the new Bonaire fan assembly, securing it with the appropriate fasteners.
  6. Reconnect Wiring: Reconnect all electrical wiring, ensuring secure and correct connections. Double-check your wiring diagram.
  7. Test and Reassemble: Restore power, verify correct operation of the fan, then reattach access panels.

Limitations & Safety Notes

  • Installation requires working with electrical components; it should only be performed by a licenced electrician or qualified HVAC technician.
  • Ensure the power supply to the unit is completely isolated and tagged out before commencing any work.
  • Verify this part number (5430805SP) matches your heater's requirements before purchase.
  • Always follow the manufacturer's installation instructions for your specific Bonaire gas heater model.

Tradie Pro Tip

Before you even touch a spanner, grab your phone and snap a few photos of the old fan's wiring. It's an easy way to avoid any headaches during reassembly, especially with different coloured wires. Don't forget to check the wiring diagram too, just in case.

Pair With

Consider pairing this fan assembly with other Bonaire heating spare parts like Bonaire Control Boards or Bonaire Wall Controllers if you're undertaking a larger service. A good quality multimeter is also essential for diagnosing electrical issues before replacement.

Common Questions for Bonaire Vulcan Gas Heater Fan Assembly 315W

This Bonaire Fan Assembly (CTSPS5430805SP) is designed for newer style Bonaire Gas Heaters. Always cross-reference the part number and wattage (315W) with your specific heater's requirements or existing component.