Hygrometers: Essential Tools

Hygrometers: Essential Tools for Managing Indoor Humidity (Australia)

Too damp or too dry air can cause health issues, mould, damaged finishes and cranky HVAC systems. A simple hygrometer shows your indoor relative humidity (RH) so you can keep it in the comfort “Goldilocks” zone.

What Is a Hygrometer?

A hygrometer measures relative humidity—how much moisture is in the air compared with the maximum the air can hold at the current temperature. Readings are shown as a percentage (%).

How It Works (Plain English)

  • Digital (capacitive/resistive sensors): An electronic sensor changes value as moisture changes; a microchip converts this into %RH.
  • Psychrometer (wet/dry bulb): Two thermometers—one wrapped in a damp wick—are compared. The temperature difference (“wet-bulb depression”) is used with a chart to find %RH.

What They Measure & Ideal Indoor Ranges

  • Relative Humidity (RH): Comfort range is typically 40–60% indoors.
  • Risks: >60% = mould, mites, swollen timber. <40% = dry skin, static, irritated airways.

Types at a Glance

Type Best for Pros Watch-outs
Digital handheld / desktop Homes, offices, greenhouses Fast, easy to read, often logs temp + RH Calibrate/check accuracy yearly
Bluetooth/app-enabled Monitoring multiple rooms or remote checks Graphs, alerts, easy sharing Keep away from vents/steam for best accuracy
Psychrometer (wet/dry bulb) Training, field verification No batteries, reliable method Needs chart and proper technique
Testo 610 pocket hygrometer measuring indoor humidity

How to Read a Hygrometer

Digital: Place the unit about 1–1.5 m above the floor, away from vents, windows and steam. Wait 2–3 minutes for the reading to stabilise.

Psychrometer: Measure dry-bulb and wet-bulb temperatures, calculate the difference, then use a psychrometric chart to find %RH.

  • Dry-bulb temperature
  • Wet-bulb temperature
  • Wet-bulb depression = dry-bulb − wet-bulb

Calibration: Quick “Salt Test”

  1. Add a teaspoon of table salt to a bottle cap, moisten (not dissolve).
  2. Place cap and hygrometer in a sealed food container for 8 hours at room temp.
  3. The air in the container should be ~75% RH. Adjust the calibration screw to 75%, or note the offset if your model can’t be adjusted.

Tip: Check calibration every 6–12 months. Analogue units drift more and need more frequent checks.

Testo 625 digital thermohygrometer tracking indoor humidity and temperature

Benefits at Home & Work

  • Health: Reduce mould and dust mites at high RH; ease dryness at low RH.
  • Comfort: Balance humidity so rooms feel cooler in summer and warmer in winter.
  • Protection: Help prevent warped timber, peeling paint and corrosion.
  • Plant care: Keep greenhouses and indoor plants in the right RH band.
  • HVAC efficiency: Optimise dehumidifiers/humidifiers and airflow settings.

Shop Hygrometers

Explore handheld, Bluetooth and pro thermohygrometers: Browse hygrometers →

Leave a comment

All comments are moderated before being published

Blog posts

View all

Mastercool Manifolds Guide

analog-manifoldRica Francia Macaspac

A manifold gauge set is the tool you reach for on every job. This guide compares Mastercool's digital and analog manifold options across 2-valve and 4-valve configurations, covering R32 compatibility, superheat and subcooling calculation, and which type suits your typical work and conditions best.

Hydraulic vs Ratchet Flaring

commercial-hvacRica Francia Macaspac

Hydraulic or ratchet? The right flaring tool depends on how many flares you're actually doing per job, not which one sounds more professional. This guide breaks down the real speed, consistency, and cost differences between Mastercool's manual and hydraulic flaring options, plus the break-even math for contractors deciding whether the hydraulic investment pays off.

How to Flare Copper

copper tube flaringRica Francia Macaspac

Learn how to flare copper tubing correctly using Mastercool flaring tools, from tube cutting and deburring through to tool setup, flare inspection, defect troubleshooting, and leak testing for reliable HVAC-R refrigerant connections.

Mastercool Flaring Tools

connection-qualityRica Francia Macaspac

A flare connection is only as good as the tool and technique behind it. This guide covers Mastercool's flaring tool range, from manual eccentric tools through to hydraulic kits, and breaks down when hydraulic earns its higher price over a traditional ratchet approach for Australian HVAC-R work.

How to Use Mastercool Pump

commissioningRica Francia Macaspac

Proper evacuation is the difference between a system that lasts and one that fails early. This step-by-step guide covers the complete Mastercool vacuum pump evacuation procedure: pre-job checks, starting the cycle, reading the micron gauge correctly, troubleshooting plateaus and leaks, and interpreting the decay test before you charge. Written for ARCtick-licensed technicians and apprentices learning the right habits from the start.

Spark-Free Vacuum Pumps for R32: Mastercool R32 Ready Guide

a2l-safetyRica Francia Macaspac

R32 is now the standard refrigerant across most Aussie HVAC-R installs — but its A2L classification means your vacuum pump needs to be spark-free, not just capable. This guide covers why standard brush-motor pumps are a safety risk on R32 systems, how spark-free brushless DC technology works, and what's actually different about evacuating an R32 system versus R22