This Brivis Spark Pilot Burner (SKU: BS80016425) is the genuine replacement part for maintaining reliable ignition in Brivis gas heaters. It's critical for service techs and competent DIYers tackling heating system repairs, ensuring your ducted gas heater fires up correctly every time. Nothing's worse than rolling up on a cold Melbourne morning only to find a faulty igniter stalling the whole system.
This assembly handles the initial spark and flame sensing, a key component for safe and efficient operation. Swapping out a tired pilot burner can often resolve intermittent ignition faults and keep your system running smoothly.
Best For
- Replacing faulty or worn-out pilot burners in Brivis gas heating systems.
- HVAC technicians performing routine maintenance or repairs on ducted gas heaters.
- Competent homeowners troubleshooting ignition issues in their Brivis heating unit.
Compatibility
This pilot burner is specifically designed for Brivis gas heating systems. It's identified as the Brivis Spark Pilot Burner Q3452B series (B016425) and is also cross-referenced with Honeywell PN: Q3452B3009. Always confirm the part number against your existing unit's specifications to ensure a correct fit.
If you're running a different model, check fittings and specs before ordering.
Features
- Genuine Brivis Part: Ensures direct fit and reliable operation as per manufacturer's design.
- Spark Pilot Burner: Provides the necessary ignition source for the main gas burner.
- Igniter Assembly: Complete unit for straightforward replacement of a faulty igniter.
- Cross-Compatible: Also known as Honeywell PN: Q3452B3009 and Brivis PN: 80016425, B016425.
What's in the Box
- 1 x Brivis Spark Pilot Burner Q3452B (Part/Code: BS80016425)
Using It on the Job
- Isolate Power and Gas: Always turn off the main power and gas supply to the heating unit before commencing any work. Implement lockout/tagout procedures.
- Access Burner Assembly: Carefully locate and access the existing pilot burner assembly within the heater.
- Disconnect & Remove: Disconnect the gas line, ignition wire, and any mounting screws. Remove the old pilot burner.
- Install New Unit: Mount the new Brivis Spark Pilot Burner, reconnect the gas line, ensuring it's properly sealed, and attach the ignition wire.
- Leak Test & Test Fire: Restore gas and power, then perform a thorough leak test on all connections. Cycle the heater to ensure proper ignition and flame sensing.
Limitations & Safety Notes
- Installation and servicing of gas appliances must be performed by a licensed professional in accordance with AS/NZS 5601 and local regulations.
- Always verify part numbers and compatibility with your specific Brivis model before replacement.
- Ensure all gas connections are leak-checked using an appropriate solution before operation.
- Disregard of safety procedures can lead to serious injury or property damage.
Before you swap out the pilot burner, always check for blockages in the pilot orifice or issues with the flame sensor. Sometimes a quick clean is all it needs, but if the spark electrode is carboned up or the ceramic is cracked, a new assembly like this is your best bet for a reliable fix.
Pair With
For comprehensive gas heater servicing, consider pairing this pilot burner with new Brivis Ignitors & Sensors or a Brivis Gas Valve. A reliable gas leak detector is also essential for safe commissioning.