This genuine Brivis pressure switch, part number BS80021375, is designed for Brivis gas ducted heating systems. It’s a critical safety component that monitors combustion airflow, ensuring your heater operates correctly and safely. A faulty pressure switch can shut down a unit or prevent it from starting, especially on those cold winter mornings when you need reliable heat the most.
Best For
- HVAC service technicians replacing faulty Brivis heater components.
- Maintenance teams working on residential or light commercial ducted gas heating.
- Competent DIY homeowners maintaining their own Brivis systems.
Compatibility
This pressure switch is specifically made for Brivis gas ducted heaters. It's identified by the part numbers NS2-1072-02 and B021375, and is rated for 140Pa. Always cross-reference the manufacturer's part number (80021375) with your existing component to ensure a perfect match. If you're running a different model, check fittings and specs before ordering.
Features
- Genuine Brivis replacement part for direct fit and reliable performance.
- Calibrated for 140Pa operation, matching original Brivis specifications.
- Critical safety component for monitoring exhaust fan operation.
- Ensures proper combustion airflow before igniting the burner.
Technical Specifications
| Specification | Detail |
|---|---|
| Part Number | BS80021375 |
| Manufacturer PN | 80021375, B021375 |
| Model Number | NS2-1072-02 |
| Pressure Rating | 140Pa |
| Compatibility | Brivis Gas Ducted Heaters |
What's in the Box
- 1x Brivis Gas Heater Pressure Switch (140Pa, NS2-1072-02)
Using It on the Job
- Isolate Power: Always shut off the main power and gas supply to the ducted heater at the breaker and gas meter before beginning work. Apply lockout/tagout procedures.
- Locate Switch: Find the existing pressure switch, typically near the combustion fan or flue pipe on the Brivis unit.
- Disconnect: Carefully disconnect the electrical wiring and any sensing tubes from the old switch. Note their original positions.
- Install New Switch: Mount the new Brivis pressure switch, reconnect the sensing tubes, and reattach the electrical wiring in the correct orientation.
- Test Operation: Restore power and gas. Initiate a heating cycle, carefully observing the sequence to ensure the combustion fan starts, the pressure switch closes, and the main burner ignites safely.
Limitations & Safety Notes
- Only for use with compatible Brivis gas ducted heating systems as specified.
- Gas appliance servicing should only be performed by a licensed gasfitter or qualified HVAC technician.
- Always follow manufacturer's installation instructions and local Australian standards.
- Ensure power and gas are fully isolated and tagged out before any maintenance.
When troubleshooting a pressure switch fault, always check the integrity of the sensing tubes for cracks or blockages first. A minor air leak in the tube can mimic a faulty switch, costing you a call-back if not properly diagnosed.
Pair With
For comprehensive gas heating servicing, pair this pressure switch with a quality digital manometer for accurate pressure diagnostics and other Brivis gas heater spares like ignitors or control boards from HVAC Shop.