These Brivis Filter Pads are essential for maintaining the performance and air quality of your Brivis Advance Series evaporative cooler. Keeping your pads fresh helps the unit cool efficiently and ensures cleaner air is circulated through the home.
After a few humid Australian summers, old pads can clog up with dust and mineral deposits, especially in hard water areas. Swapping them out is a straightforward job that keeps your system pulling its weight when it matters most.
Best For
- HVAC technicians performing routine evaporative cooler service.
- Maintenance teams for residential or light commercial properties.
- Competent DIY owners maintaining their Brivis evaporative cooler.
Compatibility
These filter pads are specifically designed for the Brivis Advance Series evaporative coolers, suitable for the following models:
- F43
- F44
- F45
- F45D
- F46
- F46DS
If you're running a different model, check fittings and specs before ordering.
Features
- Exact Fit Dimensions: Engineered to the specific size of 850mm x 485mm x 75mm for a secure seal in compatible units.
- Genuine Brivis Part: Manufactured to Brivis's specifications, ensuring optimal performance and longevity for your cooler.
- Model Specific: Designed to suit popular Brivis Advance Series models including F43, F44, F45, F45D, F46, and F46DS.
- Convenient Pack Size: Typically supplied as a set of four pads to refresh all sides of your evaporative cooler at once.
Technical Specifications
| Specification | Detail |
|---|---|
| Dimensions (L x W x H) | 850mm x 485mm x 75mm |
| Manufacturer Part Number | 81008768 |
| SKU | BS81008768 |
| Quantity | Set of 4 |
What's in the Box
- 1x Brivis Filter Pads Advance Series (Set of 4), dimensions 850mm x 485mm x 75mm each.
Using It on the Job
- Isolate Power: Always disconnect power to the evaporative cooler at the mains switchboard before commencing any work.
- Access Pads: Open the cooler's cabinet by releasing the clips or screws holding the side panels, then carefully remove the old, worn filter pads.
- Clean Cabinet: Take this opportunity to clean out any sediment, algae, or debris from the cooler's water sump and internal surfaces. Check the float valve and pump for blockages.
- Install New Pads: Carefully insert the new Brivis filter pads, ensuring they sit flush and are correctly oriented within their frames. Replace side panels securely.
- Restore Power & Test: Reconnect power and run the cooler through a cycle, checking for proper water flow over all pads and efficient cooling.
Limitations & Safety Notes
- These filter pads are designed specifically for the listed Brivis Advance Series models; use with other units is not recommended.
- Always ensure power is completely isolated before working inside the cooler's electrical components or water-filled areas.
- Regular inspection and cleaning of your evaporative cooler, including the pads, float valve, and pump, will extend its life and efficiency.
- Follow Australian standards and Safe Work guidance for all maintenance procedures.
Tradie Pro Tip
When you're replacing these pads, give the cooler's water sump a thorough clean. A bit of white vinegar in the standing water after a good scrub can help break down stubborn mineral deposits before you refill and fire it up for the season. Don't forget to check the condition of your float valve and drain system too.
Pair With
Pair with a suitable evaporative cooler cleaner and perhaps a replacement Brivis float valve for a comprehensive cooler service to prepare for the warmer months.