This Brivis Electronic Control Box TEK467 (BSB022970) is the brain for your Brivis evaporative cooling unit, ensuring all functions from fan speed to water pump activation run smoothly. It's an essential replacement part for HVAC technicians and competent DIY owners looking to restore their cooler's operation without hassle.
When an evaporative cooler starts playing up in the middle of a hot Australian summer, often the control board is the first place to look. Getting a direct fit replacement like this one saves a lot of diagnostic time.
Best For
- HVAC service technicians replacing faulty Brivis evaporative cooler control boards.
- Installers needing to swap out a defective PCB during a new unit commission.
- Competent DIY owners maintaining their own Brivis evaporative cooling systems.
Compatibility
This Brivis Electronic Control Box TEK467 is a direct replacement for Brivis Part Number B022970 and is designed to suit various Brivis evaporative cooling units. If you're running a different model, confirm the part number on your existing board before ordering.
Features
- Direct OEM replacement for Brivis Evaporative Cooling PCB TEK467.
- Ensures reliable control of all evaporative cooler functions.
- Restores full operational capability to compatible Brivis units.
- Identical fit and function to the original Brivis PN B022970.
What's in the Box
- 1 x Brivis Electronic Control Box TEK467 (BSB022970)
Using It on the Job
- Isolate Power: Always ensure the main power supply to the evaporative cooling unit is isolated and locked out before commencing any work.
- Access Control Box: Remove the unit's outer casing or access panel to expose the existing control board.
- Document Connections: Take clear photos of all wiring connections to the old board. This is crucial for correct reinstallation.
- Disconnect & Remove: Carefully disconnect all wiring harnesses and mounting screws, then remove the faulty TEK467 board.
- Install New Board: Mount the new BSB022970 control box and reconnect all wiring precisely as documented. Double-check every connection.
- Test Operation: Restore power to the unit and test all functions (fan speeds, pump, dump valve, wall controller communication) to confirm correct operation.
Limitations & Safety Notes
- Always isolate and lock out power to the unit before attempting any service or installation.
- Installation involves electrical work and should ideally be performed by a qualified HVAC technician or electrician.
- Only compatible with specified Brivis evaporative cooling units. Verify the part number (B022970) against your existing board.
- Follow all manufacturer's instructions and local electrical safety standards during installation.
Don't skip that step of photographing your wiring before you disconnect anything. It's a lifesaver when you've got a dozen wires that all look similar. A minute with your phone saves an hour of troubleshooting.
Pair With
Pair with other Brivis evaporative cooling spares like Brivis Wall Controllers, Brivis Pumps, or Brivis Fan Motors if you're undertaking a wider service or repair of your evaporative cooler.