This Braemar Fenwal Ignition Unit (SY628608) is the heart of your gas heater's start-up system, ensuring a reliable spark every time. It's a critical spare for HVAC service techs and gas appliance repairers looking to get faulty Braemar ducted heating systems back online quickly. When a unit won't ignite on a cold Melbourne morning, this is often the culprit.
Best For
- Residential Braemar gas ducted heaters.
- HVAC service and maintenance technicians.
- Gas appliance repairers.
Compatibility
This ignition unit is specifically designed for Braemar gas heating systems. It cross-references with the Fenwal 35-615300-113 ignition unit and Seeley PN: 628608. Always double-check your existing unit's part numbers to ensure a perfect match for your system. If you're running a different model, check fittings and specs before ordering.
Features
- Genuine Braemar replacement ignition board.
- Incorporates the Fenwal 35-615300-113 ignition unit for reliable spark generation.
- Direct replacement for Seeley PN: 628608.
- Essential component for consistent gas burner ignition in ducted heaters.
What's in the Box
- 1 x Braemar Fenwal Ignition Unit (SY628608)
Using It on the Job
- Isolate Power: Before touching any components, always switch off the main power to the heater and apply a lockout/tagout if working in a commercial setting.
- Access & Disconnect: Locate the existing ignition unit within the heater's control panel. Take a photo of the wiring setup before carefully disconnecting all wires and mounting screws.
- Install New Unit: Mount the new Braemar Fenwal unit in place, ensuring it's secure. Reconnect all wiring exactly as it was, making sure connections are firm.
- Test & Verify: Restore power to the heater and initiate a call for heat from the thermostat. Observe the ignition sequence to confirm a strong, consistent spark and successful burner ignition.
- Check for Gas Leaks: After any work on gas appliances, always perform a gas leak test around fittings if they were disturbed.
Limitations & Safety Notes
- Installation and servicing of gas appliances must be carried out by a qualified and licensed gasfitter in accordance with Australian Standards.
- Ensure power is fully isolated before commencing any electrical work on the unit.
- Only use this unit for the Braemar gas heating systems it is specified for.
- Always follow manufacturer's instructions for safe installation and operation.
Tradie Pro Tip
"When troubleshooting ignition issues, don't just swap the board straight away. Always check your ignitor, flame sensor, and gas valve operation first. Sometimes it's just a dirty flame sensor causing intermittent problems, not the whole unit."
Pair With
For comprehensive gas heater servicing, pair this ignition unit with new gas valves, pressure switches, or a compatible wall controller from the HVAC Shop range.