This Bonaire Vulcan fan thermostat is a direct replacement part that helps HVAC techs and competent DIYers keep Bonaire gas heaters running safely and efficiently. It ensures the circulation fan kicks in at the correct temperature.

In the Aussie heating season, a faulty thermostat can lead to short cycling or no airflow, making a house either too cold or causing nuisance faults. A properly functioning fan thermostat is crucial; you don't want the heat exchanger getting too hot while the fan sits idle on a cold winter's night.

Best For

  • Bonaire ducted gas heater service and maintenance
  • Fault finding and replacement of heater fan control
  • Preventative maintenance for Bonaire heating systems

Compatibility

This thermostat is specifically designed for Bonaire Vulcan ducted gas heaters. It's an exact match for Bonaire part number 0162630SP and is suitable for systems rated at 26mJ. If you're running a different model, check fittings and specs before ordering.

Features

  • Direct OEM replacement for Bonaire P/N 0162630SP.
  • Activates the circulation fan at 45°C to prevent overheating.
  • Essential safety component for proper ducted gas heater operation.
  • Designed for 26mJ heating systems.

Technical Specifications

Specification Detail
Activation Temperature 45°C
System Suitability Bonaire Vulcan 26mJ Gas Heaters
Bonaire Part Number 0162630SP
HVAC Shop SKU CTSPS0162630SP

What's in the Box

  • 1x Bonaire Vulcan Switch Fan Thermostat 45 Deg (CTSPS0162630SP)

Using It on the Job

  1. Always isolate power to the heating unit at the main switchboard and apply lockout/tagout procedures before commencing work.
  2. Access the existing fan thermostat location, typically near the heat exchanger.
  3. Carefully disconnect wiring from the old thermostat, noting lead placement.
  4. Remove the old thermostat and install the new CTSPS0162630SP, ensuring secure mounting.
  5. Reconnect wiring correctly, checking for tight connections.
  6. Restore power and test heater operation, verifying the fan engages and disengages as expected.

Limitations & Safety Notes

  • Ensure the thermostat's 45°C rating matches your heater's specifications before installation.
  • Only compatible with Bonaire Vulcan ducted gas heating systems as specified.
  • Electrical work should only be performed by a qualified tradesperson where required by Australian regulations.
  • Always follow the manufacturer's installation guidelines for the specific Bonaire heater model.
When replacing fan thermostats, it's a good idea to also check the fan motor and run capacitor. A failing fan can cause overheating issues that might prematurely wear out a new thermostat.

Pair With

Pair with Bonaire control boards and replacement fan motors for routine heater maintenance to keep your ducted gas system running smoothly.