Bonaire Vulcan Gas Heater Fan Assembly 250W

Regular price
$472.24
Sale price
$472.24
Regular price
$0
Sold out
Unit price
Quantity must be 1 or more

This Bonaire Vulcan Gas Heater Fan Assembly is a direct replacement unit, designed to get your ducted gas heater back to full spec without fuss. It's built for HVAC techs and competent DIY owners who need reliable Bonaire heater parts for Australian conditions.

When a Bonaire Vulcan gas heater fan starts making noise, losing push, or just cuts out, it's often the whole assembly that needs swapping. This complete kit makes the job quicker and simpler to restore proper airflow.

Best For

  • HVAC Technicians
  • Licensed Gas Fitters
  • Homeowners maintaining their Bonaire ducted gas heating system

Compatibility

This fan assembly (Bonaire PN 9241851SP) is specifically designed as a direct replacement part for Bonaire Vulcan ducted gas heaters. It integrates seamlessly with existing Bonaire heating systems to ensure proper function.

If you're running a different model, check fittings and specs before ordering.

Features

  • Complete Fan Assembly Kit for Bonaire Vulcan heaters.
  • Integrated 250 Watt motor for efficient and consistent airflow.
  • Includes pre-wired capacitor, simplifying installation.
  • Comes with mounting plate for a direct, secure fit.
  • Genuine Bonaire Part Number 9241851SP ensures proper function and longevity.

Technical Specifications

Specification Value
Motor Wattage 250W
Bonaire Part Number 9241851SP

What's in the Box

  • Bonaire Vulcan Gas Heater Fan Assembly
  • 250W Motor
  • Mounting Plate
  • Capacitor

Using It on the Job

  1. Isolate Power: Always disconnect mains power to the heater at the circuit breaker and use a lockout tagout device before beginning any work.
  2. Access Panel: Carefully remove the heater's access panels to expose the existing fan assembly.
  3. Disconnect: Unplug the existing fan assembly's electrical connections and carefully unmount it from the heater cabinet.
  4. Install New Assembly: Mount the new Bonaire fan assembly into place and reconnect all electrical wiring. Ensure all connections are secure.
  5. Test & Reassemble: Restore power and test the heater's operation. Once confirmed, reattach all access panels securely.

Limitations & Safety Notes

  • Electrical work should only be performed by competent persons or licensed electricians.
  • Always ensure mains power is isolated before working on any heating appliances.
  • This assembly is designed only for compatible Bonaire Vulcan gas heaters as specified.
  • Follow all Australian electrical and gas safety standards during installation and service.
Before you even touch a spanner, grab your multimeter and confirm power is off at the terminals. A quick double-check here saves a trip to the ER. Also, give the new fan wheel a spin by hand; sometimes a bit of transport grit can be sitting there.