Built for tradies: The Embraco Aspera NEU6212GK is a compact, hermetic R134a HBP compressor sized for display fridges, reach-ins and small merchandisers. It helps licensed techs get reliable pull-down, fewer call-backs and cleaner installs — no dramas.
With CSIR high start torque, it kicks over on warm heads and tight systems so you’re off the ladder faster and onto the next job. Too easy.
Key Features & Trade Benefits
- R134a HBP application — built for merchandisers and reach-ins; stable cabinet temps and fewer nuisance call-backs.
- CSIR high-start-torque motor — clean starts under load in warm shops; reduces breaker trips and “come back tomorrow” headaches.
- Displacement: ~8.77–8.78 cm³ — right in the sweet spot for common single-cabinet duties.
- Factory oil charge: POE ISO 22 (~350 ml) — ready for evacuation and weighed charge on R134a systems.
- Compact UNI base & service stubs — typical stubs: 8.1 mm suction / 6.1 mm discharge & process for quick, clean brazes.
- Lightweight form factor — height ~200 mm, weight ~10.6 kg, easy to handle in tight cavities.
Why This Product Matters
Trade yarn: steamy arvo in Brisbane and the drinks merchandiser kept drifting up around lunch. We swapped in a NEU6212GK, fitted a fresh drier, nitrogen-pressure-tested, pulled to <500 microns and weighed the charge — case temps were back on setpoint before smoko. Fair dinkum difference when the duty and application match.
Need broader spares? Browse our Refrigeration collection for tools and parts that keep systems humming.
Pro Tip
Replace the liquid-line drier and purge with nitrogen while brazing. Verify with a decay test after hitting target microns. Log SH/SC and weigh the charge — you’ll cut call-backs and keep customers happy. No worries.
Compatibility & System Info
- Refrigerant: R134a (HBP). Always confirm the engineering code on the nameplate — some NEU6212GK variants are factory-optimised for R404A MBP/HBP.
- Systems: Cap tube or TXV; display fridges, reach-ins, beverage merchandisers.
- Electrical: 220–240 V, 50 Hz, single-phase; CSIR (high start torque). Typical start capacitor: 53–64 µF / 330 V.
- Local note: In Sydney humidity and Perth summer heat, keep condensers clean and confirm fan direction/airflow post-install to keep head pressure sensible.
What’s Included
- Embraco NEU6212GK hermetic compressor (factory-filled ~350 ml POE ISO 22)
- Motor protection/relay per kit
- Installation leaflet (where supplied)
- Note: Start components/grommets may be sold separately — check box contents on delivery.
Specifications
Item | Spec |
---|---|
Model / Eng. code (typ.) | NEU6212GK / 958HA51… (e.g., 958HA51M1AJ) |
Power supply | 220–240 V, 50 Hz, 1-ph |
Application | HBP (R134a); verify code if R404A MBP/HBP |
Displacement | ~8.77–8.78 cm³ |
Height / Weight | ~200 mm / ~10.6 kg |
Oil / charge | POE (ester) ISO 22 / ~350 ml |
Start components | CSIR; start capacitor 53–64 µF / 330 V (typ.) |
LRA (typ.) | ~19 A |
Tube stubs (typ.) | Suction Ø 8.1 mm; Discharge Ø 6.1 mm; Process Ø 6.1 mm |
Base | UNI (European) |
Performance reference | Example: ~0.83 kW @ −10 °C evap (R404A condensing unit with NEU6212GK); ~1.21 kW @ 0 °C. Use as orientation only — confirm for R134a duty. |
Specs and figures drawn from Embraco technical data and distributor documentation; confirm against the compressor nameplate for the exact code supplied.
Warranty & Returns
Backed by manufacturer warranty. See our Shipping & Returns policy. Standard Australian consumer guarantees apply.
FAQs
Often, yes if the duty matches. Check base footprint (UNI), tube sizes (8.1/6.1 mm), and capacity at your design temps. Replace the drier, evacuate properly and weigh the charge.
Typical CSIR start cap is 53–64 µF / 330 V. Confirm the supplied kit and the nameplate for your unit.
This listing covers R134a HBP duties. Some engineering codes for NEU6212GK target R404A MBP/HBP — always verify the nameplate and follow AU licensing and the AIRAH code of practice for safety and compliance.
Related Products
- Bradley NR1000 High-Pressure Nitrogen Regulator — helps you dial in a stable test pressure before every evac.
- Vacuum Pumps (collection) — pick a pump that hits and holds <500 microns for dry systems.
- Refrigerant Gauges (collection) — charge accurately, log SH/SC and cut call-backs.
- Embraco NEU6215GK — handy alternative if you need a touch more capacity.
For AU/NZ compliance and handling guidance, see AIRAH’s Refrigerant Handling Codes of Practice.