Collection: HVAC Shop - Regulators
- Mastercool Nitrogen Pressure Testing Regulator Kit 53040
- +sp.priceRaw ? 'price price--on-sale' : 'price'">
- Regular price
- $532.00
- Sale price
- $532.00
- Regular price
-
$669.99
Sold out - Mastercool Nitrogen Pressure Regulator Australia 53004
- +sp.priceRaw ? 'price price--on-sale' : 'price'">
- Regular price
- $386.95
- Sale price
- $386.95
- Regular price
-
$483.95
Sold out
Nitrogen Pressure Regulators for HVAC Leak Testing
Need reliable nitrogen pressure testing for HVAC and refrigeration systems? These Mastercool nitrogen regulators and test kits are purpose-built for oxygen-free, dry nitrogen leak testing, purging and commissioning in Australian conditions, including R32 and R410A systems when used to manufacturer and ARC code requirements.
Shop nitrogen pressure regulators for Aussie HVAC work
For pressure testing, you want a regulator that’s built for HVAC/R – not just a generic industrial gas reg. These Mastercool options give you stable control, clear gauges and the right outlet connections for common HVAC hoses and adaptors.
Mastercool 53040 Nitrogen Pressure Testing Regulator Kit
Best for techs who want a complete leak testing setup in one case.
- Dual easy-read gauges with protective guards for high and low pressure monitoring.
- High pressure gauge rated for cylinder pressure; low pressure gauge up to 1000 psig (70 bar) for test pressure control.
- 1/4" SAE flare outlet with control valve to keep pressure stable at the regulator.
- Includes yellow charging hose, leak testing adaptor, R410A/R32 straight adaptor (1/4" FL-M x 5/16" swivel-F) and a durable blow-moulded carry case.
See the full spec sheet on the Mastercool Nitrogen Pressure Testing Regulator Kit 53040 .
Mastercool 53004 Nitrogen Pressure Regulator (Australia)
Ideal if you already own hoses and adaptors and just need a solid, single-stage nitrogen regulator.
- Designed specifically for HVAC/R and automotive A/C nitrogen testing applications.
- Single-stage nitrogen regulator for leak testing systems before refrigerant charging.
- Compatible with Australian cylinder connection standards, with a 1/4" flare outlet suited to HVAC hoses.
- Robust construction with protected gauges for on-site durability.
Prefer to build your own hose setup? Choose the Mastercool Nitrogen Pressure Regulator Australia 53004 .
When to use a nitrogen pressure regulator
Oxygen-free dry nitrogen (OFN) is widely recommended in Australia for pressure testing, leak checks and brazing purges on refrigeration and air conditioning systems, to minimise moisture and oxidation inside the pipework.
Leak and strength testing after installation or repair
- Pressurise the system with dry nitrogen to an appropriate test pressure relative to the refrigerant and system design (always follow the equipment manufacturer’s instructions and applicable codes of practice).
- Monitor pressure stability over time to confirm there are no leaks before evacuation.
- Combine nitrogen pressure testing with electronic leak detection and/or bubble solution, as recommended in the refrigerant handling codes of practice.
Nitrogen purging during brazing
Keeping a low, controlled nitrogen flow through the line set while brazing helps reduce internal oxidation (scale) and supports long-term energy efficiency and reliability by keeping the system drier and cleaner. Set the regulator for a low, steady flow rather than full pressure, and always follow manufacturer instructions.
Reducing emissions and protecting the environment
Good nitrogen pressure testing helps cut refrigerant leakage, which is a key source of synthetic greenhouse gas emissions from the RAC sector. Leak-free, efficient systems also support broader building energy-efficiency and retrofit goals across Australia.
How to choose the right nitrogen regulator
- Cylinder compatibility: Check the regulator suits your cylinder connection standard (e.g. Australian AS 2473.2 gas fittings). Mastercool’s Australian nitrogen regulator models are designed for local fittings.
- Outlet connection & hose setup: For HVAC, a 1/4" SAE flare outlet makes it easy to connect charging hoses and adaptors. If you don’t already own hoses and R32/R410A adaptors, choose the 53040 kit, which includes them.
- Gauge range & resolution: Ensure the low-side gauge comfortably covers your intended test pressure while still giving fine control, so you can see small pressure changes that may indicate leaks.
- Single regulator vs complete kit: Pick the 53004 regulator-only model if you already have hoses and adaptors, or the 53040 kit if you want an all-in-one nitrogen testing setup.
- Safety & compliance: Secure cylinders upright, store them away from heat and incompatible chemicals, and follow ARC refrigerant handling codes of practice and manufacturer instructions for pressure limits, system isolation and leak-testing methods.
Licensing note: If you’re pressure testing systems that contain or will contain scheduled refrigerants, Australian regulations generally require you to hold an appropriate ARCtick refrigerant handling licence or work under a licensed entity. When in doubt, check with ARC or your state WHS regulator.
Pair your nitrogen regulator with the right tools
To build a complete leak testing and commissioning kit, pair your nitrogen regulator with:
- Digital or analogue manifold gauges for accurate pressure monitoring and superheat/subcool checks – browse the Manifold, AC & Refrigerant Gauges collection.
- A quality vacuum pump for evacuation once the system passes nitrogen pressure testing – see the Refrigerant Vacuum Pump collection, and link through to your “How to Set Up a Vacuum Pump” guide for a step-by-step workflow.
- Leak detection tools such as electronic detectors and leak-detection spray, aligned with ARC recommendations to use electronic leak detection as your primary method and spray as point-source verification.
Why buy nitrogen regulators from HVAC Shop
- Specialist HVAC focus: You’re buying from a store dedicated to HVAC and refrigeration tools, not generic gas hardware.
- Mastercool & pro brands: Stocking brands that HVAC technicians already rely on in the field.
- Fast Australian shipping & support: Clear contact details, local support hours and nationwide delivery make it easy to get help when you need it.
- Education-backed content: Your blog covers commissioning tools like digital manifolds and vacuum pumps, so this regulators collection is part of a wider knowledge hub for tradies and advanced DIYers.
Frequently Asked Questions
What nitrogen test pressure should I use on an R32 or R410A system?
Always follow the equipment manufacturer’s instructions and the applicable refrigerant handling codes. Many modern systems are pressure tested with dry nitrogen to around 3000 kPa (about 435–450 psi), but you must confirm the exact test pressure on the unit’s data plate and documentation before setting your regulator.
Can I use oxygen or compressed air instead of nitrogen for leak testing?
No. Oxygen and compressed air introduce moisture and can create serious fire or explosion risks. Australian guidance specifies oxygen-free dry nitrogen (OFN) or an approved nitrogen/hydrogen mix as the correct pressure-test medium for refrigeration and air conditioning systems.
Are these nitrogen regulators suitable when working with R32 and other A2L refrigerants?
Yes, because the regulators only control nitrogen, not refrigerant. They are used to pressure test or purge the system before charging. When working with R32 and other A2L refrigerants you must still follow all relevant flammable refrigerant safety requirements and stay within the system’s rated pressures.
Do I need an ARCtick licence to use a nitrogen regulator on an AC system?
If you are working on systems that contain or will contain controlled refrigerants, Australian regulations generally require you to hold an appropriate ARCtick refrigerant handling licence or work under a licensed entity. Leak testing and repairs on RAC systems are considered licensed work, so check with ARC or your state regulator if you are unsure.
What other gear do I need with a nitrogen regulator?
A typical HVAC leak-testing setup includes a nitrogen cylinder (oxygen-free dry nitrogen), a suitable nitrogen regulator or test kit, charging hose and adaptors, manifold or digital gauges, leak detection tools, and a vacuum pump with micron gauge for evacuation after the nitrogen test.
How should I store and transport nitrogen cylinders safely?
Store and transport nitrogen cylinders upright, secured against movement, away from heat sources and incompatible hazardous chemicals, and in line with Safe Work and state WorkSafe guidance on compressed gases. Ensure vehicles are well ventilated and remove cylinders promptly at the destination.
Author: HVACShop Content Team – HVAC content specialist
Technical review: Licensed refrigeration & air conditioning technician ARCtick
Business: HVACShop.com.au • ABN 98 351 143 900
Contact: hvacshop.com.au@gmail.com • 0412 333 115 (Mon–Fri, 9:00am–5:00pm AEST)
Last updated: 2025-12-04 (UTC+11:00, Australia/Sydney)