{"product_id":"yellow-3-metre-charge-hose-with-ball-valve-cb-cel300cha","title":"Yellow 3-Metre Charge Hose with Ball Valve","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis yellow 3-metre charge hose, fitted with an integrated ball valve, is a solid choice for Australian HVAC\/R technicians. It helps you accurately charge and recover refrigerant on split systems and commercial units, providing an extra layer of control right at the connection point.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHaving a reliable hose with a ball valve means you can minimise refrigerant loss and quickly isolate the line, especially useful when working on a busy rooftop under the Australian sun. This particular hose's details, including its 3-metre length and yellow colour, are inferred directly from its SKU, CB-CEL300CHA, as specific manufacturer data was unavailable.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC\/R service technicians\u003c\/li\u003e\n\u003cli\u003eRefrigeration apprentices\u003c\/li\u003e\n\u003cli\u003eMaintenance teams managing HVAC systems\u003c\/li\u003e\n\u003cli\u003eAnyone performing refrigerant charging or recovery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhile specific manufacturer compatibility data for SKU CB-CEL300CHA was not provided, this type of charge hose is typically designed for use with standard HVAC\/R manifold gauge sets and vacuum pumps. It's generally suitable for common refrigerants like R32 and R410A, and often features industry-standard 1\/4\" SAE fittings on the manifold end and a 1\/4\" SAE or 5\/16\" SAE fitting on the system end for connection to service ports. If you're running a different model or working with specific refrigerants, always check the exact fitting sizes and pressure ratings before ordering to ensure it meets your system's requirements.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Ball Valve:\u003c\/strong\u003e Allows for quick isolation of the line, minimising refrigerant loss and improving control during service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Metre Length:\u003c\/strong\u003e Provides ample reach for various service applications, reducing the need to reposition your manifold or tanks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Designed to withstand the high pressures and chemical exposure common in HVAC\/R work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReinforced Connections:\u003c\/strong\u003e Engineered to provide a secure, leak-free seal on manifold gauges and system ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eNo specific technical specifications (e.g., precise pressure ratings, material composition, or exact fitting types beyond general industry standards) were available in the provided manufacturer's data for SKU CB-CEL300CHA. Users are advised to verify compatibility for their specific applications.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x Yellow 3-Metre Charge Hose with Ball Valve (SKU: CB-CEL300CHA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Before Use:\u003c\/strong\u003e Always check your hose for cuts, kinks, or damaged seals before connecting. A failing hose is a risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Securely:\u003c\/strong\u003e Attach the appropriate end to your manifold gauge set and the other to the system's service port. Ensure all flare nuts are tightened correctly, but don't overtighten and damage the seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum\/Pressure Test:\u003c\/strong\u003e If performing an evacuation, open the ball valve fully. For pressure testing, make sure the ball valve is open to allow nitrogen flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge\/Recover:\u003c\/strong\u003e Control refrigerant flow using your manifold valves and the hose's ball valve for finer adjustment and isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimise Loss:\u003c\/strong\u003e Use the ball valve to close off the hose before disconnecting from the service port to keep refrigerant where it belongs and reduce atmospheric release.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean and Store:\u003c\/strong\u003e After use, wipe down the hose to remove any oil or grime and store it in a way that prevents kinking or damage to the fittings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eWorking with refrigerants requires a current ARCtick licence in Australia. Always comply with relevant regulations.\u003c\/li\u003e\n\u003cli\u003eAlways confirm the hose's pressure rating is suitable for the system and refrigerant you are working with.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the manufacturer's recommended working pressure for the hose.\u003c\/li\u003e\n\u003cli\u003eRegularly inspect the hose and its seals for wear and tear. Replace immediately if damage is found.\u003c\/li\u003e\n\u003cli\u003eAlways wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when handling refrigerants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\u003cstrong\u003eTradie Pro Tip:\u003c\/strong\u003e Before connecting your charge hose to a system, slightly open the manifold valve and purge the air out of the hose. This small step prevents non-condensables from entering the refrigerant circuit, saving you potential headaches down the track.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this charge hose with a quality digital manifold gauge set, a reliable vacuum pump, and a precise refrigerant scale for accurate and efficient system servicing. For those working with different refrigerant types or connection requirements, check out our range of manifold gauge sets and vacuum pump oil.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What refrigerants and fitting sizes is this hose compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Based on its common application, this charge hose is generally compatible with common refrigerants like R32 and R410A. It typically features standard 1\/4\\\" SAE fittings, often with a 5\/16\\\" SAE option for R410A systems. Always verify the specific fittings on your manifold and system service ports before purchase, as detailed manufacturer data was not available for SKU CB-CEL300CHA.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is included with the purchase of SKU CB-CEL300CHA?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The purchase of SKU CB-CEL300CHA includes one yellow 3-metre charge hose with an integrated ball valve. Due to the unreadable nature of the original manufacturer data, no additional accessories or components are specified as being included with this product.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How should I care for my charge hose to ensure longevity?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"To maximise the life of your charge hose, always inspect it for damage before each use and clean off any refrigerant oil or grime afterward. Store it unkinked in a protected environment, away from direct sunlight or extreme temperatures, to prevent material degradation. Regularly check and replace any worn O-rings in the fittings.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Coolbreeze","offers":[{"title":"Default Title","offer_id":43748459511867,"sku":"CB-CEL300CHA","price":354.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/cel301cha-300x300.jpg?v=1783309881","url":"https:\/\/www.hvacshop.com.au\/products\/yellow-3-metre-charge-hose-with-ball-valve-cb-cel300cha","provider":"HVAC Supply Shop","version":"1.0","type":"link"}