{"product_id":"type-5-glass-ph-electrode-with-integrated-temperature-sensor-0650-1623","title":"Type 5 Glass pH Electrode with Integrated Temperature Sensor","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Testo Type 5 Glass pH Electrode with integrated temperature sensor is built for reliable, precise water quality measurements. It’s ideal for HVAC technicians and water treatment specialists who need to accurately monitor pH and temperature in various industrial applications.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHaving a robust, dirt-insensitive pH probe on hand is crucial when you're testing water loops that might contain suspended solids or other contaminants, helping you quickly identify issues before they cause system damage.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC water treatment and facility maintenance\u003c\/li\u003e\n\u003cli\u003eIndustrial process control and monitoring\u003c\/li\u003e\n\u003cli\u003eWater quality analysis in cooling towers, boilers, and closed loops\u003c\/li\u003e\n\u003cli\u003eAny application requiring accurate pH and temperature readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Testo pH electrode is designed to work seamlessly with compatible Testo instruments, such as the Testo 230 (as mentioned in manufacturer specs). Always ensure your existing Testo meter supports this probe type for proper function.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Engineered with a single-pore diaphragm, making it resilient against dirt and suspended solids common in industrial water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass Electrode Design:\u003c\/strong\u003e Offers excellent chemical resistance, ensuring longevity and accuracy across a range of applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Free Gel-Electrolyte:\u003c\/strong\u003e Simplifies operation and reduces the need for constant refilling, saving you time on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Temperature Sensor:\u003c\/strong\u003e Provides simultaneous temperature readings for complete water analysis and accurate pH compensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0 to 14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e-10 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eElectrode Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eGlass, single-pore diaphragm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eElectrolyte\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eGel, maintenance-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eTesto 0650 1623 Type 5 Glass pH Electrode with Temperature Sensor\u003c\/li\u003e\n\u003cli\u003eStorage Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the Electrode:\u003c\/strong\u003e Remove the storage cap carefully. If dry, condition the electrode by soaking it in a suitable storage solution or buffer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect to Meter:\u003c\/strong\u003e Firmly attach the electrode to your compatible Testo pH meter. Ensure the connection is clean and dry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrate:\u003c\/strong\u003e Perform a two-point (or three-point for higher accuracy) calibration using known pH buffer solutions (e.g., pH 4, 7, and 10). Always calibrate regularly, especially for critical measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTake Measurements:\u003c\/strong\u003e Submerge the electrode into the water sample, ensuring both the pH sensor and temperature sensor are fully immersed. Allow readings to stabilise before recording.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean \u0026amp; Store:\u003c\/strong\u003e After use, rinse the electrode with distilled or deionised water. Replace the storage cap, ideally with some storage solution inside, to keep the glass bulb hydrated.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eThis electrode contains a glass bulb, which is fragile and can break if dropped or mishandled.\u003c\/li\u003e\n\u003cli\u003eAlways use appropriate PPE (e.g., gloves, eye protection) when handling chemicals or water samples that may be hazardous.\u003c\/li\u003e\n\u003cli\u003eEnsure the electrode is only used within its specified temperature and pH range to prevent damage and ensure accurate readings.\u003c\/li\u003e\n\u003cli\u003eRegular calibration with fresh buffer solutions is essential for maintaining measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eAlways keep your pH electrode's storage cap properly filled with a dedicated storage solution, not just water. It prevents the reference junction from drying out and extends the life and accuracy of your probe. A dry electrode gives you nothing but headaches and dodgy readings.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this pH electrode with a compatible Testo pH meter, pH buffer solutions for calibration, and an electrode storage solution to keep it in top condition.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43799310991419,"sku":"0650 1623","price":812.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/xtesto-0650-1623-type-5-glass-ph-electrode-with-temperature-sensor.jpg.pagespeed.ic.wCKpWA3kwD.jpg?v=1784272717","url":"https:\/\/www.hvacshop.com.au\/products\/type-5-glass-ph-electrode-with-integrated-temperature-sensor-0650-1623","provider":"HVAC Supply Shop","version":"1.0","type":"link"}