{"product_id":"testo-pitot-tube-3-3ft-stainless-steel-0635-2345","title":"Testo 3.3 ft Stainless Steel Pitot Tube","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Testo 3.3 ft (1000 mm) stainless steel pitot tube is purpose-built for accurate airflow velocity measurement in demanding HVAC and industrial environments. It's a solid bit of kit for any tech or engineer needing reliable data on duct systems.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen you're dealing with dusty rooftop units or contaminated exhaust stacks here in Australia, you need a probe that can take a beating and still give a true reading. This pitot tube is up to the task.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service and installation technicians\u003c\/li\u003e\n\u003cli\u003eIndustrial process engineers\u003c\/li\u003e\n\u003cli\u003eBuilding commissioning specialists\u003c\/li\u003e\n\u003cli\u003eMaintenance teams measuring duct airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis pitot tube is designed to integrate with compatible differential pressure measurement devices, requiring a connection hose and a suitable pressure probe for full functionality. It's ideal for use with Testo's range of handheld meters and combustion analysers that support differential pressure inputs.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Stainless Steel Construction:\u003c\/strong\u003e Built to withstand harsh industrial and commercial environments, ensuring long-term durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000 mm Length:\u003c\/strong\u003e Provides ample reach for accurate measurements in larger ducts and exhaust systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for High Flow Velocity:\u003c\/strong\u003e Delivers precise readings even in rapid airflow applications where other methods might struggle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandles Contaminated Flow:\u003c\/strong\u003e Its design allows for effective measurement in heavily particulate-laden air streams without clogging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7 mm Shaft Diameter:\u003c\/strong\u003e Slim profile allows for easier insertion into test ports with minimal impact on airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e235 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0 to +600 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Diameter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProduct Colour\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x Stainless Steel Pitot Tube, Ø 7 mm, 1000 mm length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare Equipment:\u003c\/strong\u003e Ensure your differential pressure gauge is calibrated and ready. Connect the pitot tube to your gauge via appropriate connection hoses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentify Test Point:\u003c\/strong\u003e Select a suitable measurement point in the duct, ideally a straight section with minimal turbulence. Drill or use an existing access port large enough for the 7 mm probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert Pitot Tube:\u003c\/strong\u003e Carefully insert the pitot tube into the duct, ensuring the tip faces directly into the airflow. Position it at the centre or other specified points for an accurate traverse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTake Readings:\u003c\/strong\u003e Record the differential pressure reading from your connected gauge. Use appropriate calculations or your gauge's internal functions to convert this to airflow velocity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove \u0026amp; Store:\u003c\/strong\u003e Once measurements are complete, carefully remove the pitot tube. Wipe it clean, especially if used in contaminated environments, and store it safely to prevent damage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways ensure the pitot tube is correctly connected to the differential pressure instrument before insertion.\u003c\/li\u003e\n\u003cli\u003eDo not use the probe in explosive atmospheres unless explicitly rated for such conditions.\u003c\/li\u003e\n\u003cli\u003eBe aware of high temperatures within ducts; always use appropriate PPE.\u003c\/li\u003e\n\u003cli\u003eThis pitot tube is a measuring accessory and requires a separate pressure probe and connection hoses for full functionality.\u003c\/li\u003e\n\u003cli\u003eFollow all Australian workplace safety standards and manufacturer guidelines during use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eTo get reliable readings in dirty ducts, always double-check that the pitot tube's measuring ports are clear before and after use. A blocked port will give you bogus numbers, wasting your time and potentially leading to incorrect system adjustments.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this pitot tube with a quality differential pressure gauge, suitable connection hoses, and a drilling tool for creating access points to complete your airflow measurement kit. You might also want to look at our range of airflow meters for alternative measurement methods.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What other equipment do I need to use this pitot tube?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This pitot tube requires a compatible differential pressure measurement device, a pressure probe, and connection hoses to function. It serves as the primary sensor for detecting airflow velocity.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What are the key dimensions and operating temperature for this pitot tube?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The probe shaft is 1000 mm (3.3 ft) long with a 7 mm diameter. It is designed to operate in temperatures ranging from 0 to +600 \\u00b0C.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this pitot tube suitable for contaminated airflow environments?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, this stainless steel pitot tube is specifically designed for effective airflow velocity measurement in environments with high flow velocities and heavily contaminated air streams, resisting clogging and corrosion.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43761015291963,"sku":"0635 2345","price":1383.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/0635-2145-probe-velocity-001751_cbb1e56d-e2d4-4190-9851-60f70a8a2632.png?v=1783575337","url":"https:\/\/www.hvacshop.com.au\/products\/testo-pitot-tube-3-3ft-stainless-steel-0635-2345","provider":"HVAC Supply Shop","version":"1.0","type":"link"}