{"product_id":"testo-minidin-connection-cable-0554-5520","title":"Testo MiniDIN Connection Cable","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Testo MiniDIN connection cable is built to link your Testo 552 Digital Vacuum Gauge directly to a Testo 570 Digital Manifold. It's a key component for techs needing more precise vacuum readings and reliable data logging during field service. Having the right cable on hand prevents frustrating delays, especially when you're under the pump on a hot Australian summer day.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis cable ensures your Testo instruments communicate effectively, making critical evacuation work smoother and more accurate.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eHVAC technicians and refrigeration mechanics\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eService teams using Testo 552 vacuum gauges and 570 digital manifolds\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eApprentices learning digital manifold system operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis cable is designed specifically for connecting the \u003cstrong\u003eTesto 552 Digital Vacuum Gauge\u003c\/strong\u003e to the \u003cstrong\u003eTesto 570 Digital Manifold\u003c\/strong\u003e. It features MiniDIN connections on both sides, ensuring a secure and reliable link between these compatible instruments. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eDirect Compatibility\u003c\/strong\u003e: Engineered to link Testo 552 vacuum gauges with Testo 570 digital manifolds.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eEnhanced Vacuum Readout\u003c\/strong\u003e: Provides the Testo 570 manifold with a higher resolution vacuum reading from the connected 552 gauge.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eData Logging \u0026amp; Printing\u003c\/strong\u003e: Enables the 570 manifold to store and print measurements taken by the 552 vacuum gauge, streamlining report generation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eSecure MiniDIN Connectors\u003c\/strong\u003e: Features robust MiniDIN connections on both ends for a reliable, tight fit that won't easily dislodge.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eOptimal Length\u003c\/strong\u003e: Generous 1.46 metre (approximately 57.5 inches) cable provides flexibility on diverse job sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e46 g (1.62 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1.46 m (57.48 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMiniDIN (both sides)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProduct Colour\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e1 x Testo MiniDIN Connection Cable (1.46 m length)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEnsure both your Testo 552 vacuum gauge and Testo 570 manifold are powered off before attempting to connect the cable.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eLocate the MiniDIN ports on both devices. These are typically clearly marked to avoid confusion.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eCarefully insert one end of the cable into the Testo 552 and the other into the Testo 570 until they click securely into place. Never force the connections to avoid damaging the pins.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eOnce connected, power on your devices. The manifold should now recognise the connected vacuum gauge for enhanced readings and data functions.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAfter completing your vacuum measurements, power off both devices before disconnecting the cable. This helps to prevent wear and tear on the delicate ports and pins.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eThis cable is only for use with the specified Testo 552 Digital Vacuum Gauge and Testo 570 Digital Manifold models. Compatibility with other Testo instruments or third-party devices is not guaranteed.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eHandle cables carefully to avoid kinks, sharp bends, or damage to the connectors, which can lead to intermittent readings or signal loss.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAlways keep the MiniDIN connections clean and free from dirt, dust, or moisture to ensure reliable signal transmission and prevent corrosion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\"Always coil your cables neatly after use. Tossing them into the bottom of the toolbox can lead to damaged pins and signal drops just when you need them most on a critical vacuum. A tidy cable is a reliable cable.\"\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with Testo digital manifold gauges, high-quality vacuum pumps, and a range of other Testo accessories for comprehensive HVAC system diagnostics and servicing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Testo devices is this cable compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This MiniDIN connection cable is designed specifically to link the Testo 552 Digital Vacuum Gauge with the Testo 570 Digital Manifold. It ensures seamless communication between these two instruments for enhanced functionality.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the length of this MiniDIN cable?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The cable is 1.46 metres (or approximately 57.48 inches) long. This provides sufficient reach and flexibility for connecting your Testo instruments comfortably during field service and diagnostic work.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What are the main benefits of using this cable?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Connecting your Testo 552 to a Testo 570 via this cable enables the manifold to display a higher resolution vacuum reading from the gauge. It also allows the 570 to store and print the precise measurement data captured by the 552.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43550741561403,"sku":"0554 5520","price":71.18,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/0554-5520-accessory-others-005334-27449_dc624d34-c21b-4299-a025-bd7220b41d81.jpg?v=1779863482","url":"https:\/\/www.hvacshop.com.au\/products\/testo-minidin-connection-cable-0554-5520","provider":"HVAC Supply Shop","version":"1.0","type":"link"}