{"product_id":"testo-industrial-flue-gas-probe-kit-1200c-0600-7610","title":"Testo Industrial Flue Gas Probe Kit 1200°C","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Testo Industrial Flue Gas Probe Kit is built tough for Aussie industrial environments, letting you safely sample exhaust gases up to 1200°C for accurate emissions analysis. It’s an essential bit of kit for anyone running a Testo 340 or 350 analyser in challenging high-temperature applications.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eFrom measuring furnace atmospheres to checking plant efficiency, this probe kit ensures you get reliable data without putting yourself in harm's way. I've seen probes buckle under sustained high heat, but this unit is designed to hold up to the serious temperatures found in industrial flues.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIndustrial emissions technicians and environmental monitoring teams.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC commissioning specialists working on large industrial plants.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePlant maintenance crews monitoring furnace efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis industrial probe kit is specifically designed to integrate seamlessly with your Testo 340 and Testo 350 Emission Analyzers. It’s perfect for extractive sampling of flue gas in industrial setups with high flue gas temperatures of up to 1200°C and large pipe diameters. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eHigh-Temperature Rating:\u003c\/strong\u003e Handles flue gas temperatures up to a scorching 1200°C (2192°F) without issues.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Features a durable metal housing and steel handle for industrial longevity.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eIntegrated Filtration:\u003c\/strong\u003e Comes with a 4-metre gas sampling hose including an inline filter to protect your analyser from contaminants.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eType K Thermocouple:\u003c\/strong\u003e Includes a reliable Type K thermocouple for accurate temperature measurements.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eExtendable Design:\u003c\/strong\u003e The 1-metre sampling tube can be extended up to 3 metres using optional extension tubes for deeper access into large flues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMaximum Flue Gas Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1200 °C (2192 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1053 mm (1.053 metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Diameter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eGas Sampling Hose Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e4 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1190 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProduct Colour\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBlack, Silver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIndustrial probe handle (steel)\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e1 metre (39 inch) unheated probe shaft for 1200 °C flue gas\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e4 metre (13 foot) gas sampling hose with inline filter\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThermocouple type K\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eBefore entering any industrial flue or high-temperature area, ensure all necessary permits are in place and appropriate PPE is worn.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eConnect the gas sampling hose to your Testo 340 or 350 analyser, ensuring the inline filter is correctly installed and free from blockages.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eInsert the probe shaft into the flue. For deeper penetration, attach optional extension tubes and thermocouple type K accessory as needed.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePerform your emissions measurements or temperature readings according to the analyser's instructions and plant protocols.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAfter use, allow the probe to cool. Clean any particulate buildup from the probe shaft and check the inline filter for contamination. Replace filters as required.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis probe is rated for flue gas temperatures up to 1200 °C. Do not exceed this limit.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eOnly use this probe kit with compatible Testo 340 or Testo 350 Emission Analyzers.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAlways follow site-specific safety procedures and Australian Standards for working in high-temperature or hazardous environments.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eEnsure the gas sampling hose is free from kinks or damage that could affect sample integrity or analyser performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen you're dealing with high dust loads in a flue, seriously consider grabbing the optional preliminary filter. It'll save your analyser's internal filters and sampling lines a heap of abuse, extending the life of your expensive gear and reducing maintenance downtime.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this industrial probe kit with a Testo 340 or Testo 350 Emissions Analyser and spare particle filters to ensure you're always ready for reliable emissions monitoring. Consider adding an optional probe extension tube for those really deep flues.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What's the maximum temperature this probe can handle?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This industrial flue gas probe kit is engineered to safely handle and measure flue gas temperatures up to 1200 \u0026deg;C (2192 \u0026deg;F). It's built for demanding high-heat industrial applications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which Testo analysers is this probe compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The 0600 7610 probe kit is designed for full compatibility with both the Testo 340 and Testo 350 Emission Analyzers. It integrates directly for seamless flue gas sampling.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can the probe shaft or sampling hose be extended?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, the 1-metre probe shaft can be extended up to a total of 3 metres using optional extension tubes. The standard 4-metre gas sampling hose can also be extended with additional hose extensions sold separately.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43761013653563,"sku":"0600 7610","price":6245.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/0600-7610-probe-emission-005209.png?v=1783575326","url":"https:\/\/www.hvacshop.com.au\/products\/testo-industrial-flue-gas-probe-kit-1200c-0600-7610","provider":"HVAC Supply Shop","version":"1.0","type":"link"}