{"product_id":"testo-206-ph2-ph-and-temperature-meter-0563-2062","title":"Testo 206-pH2 pH and Temperature Meter","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThe Testo 206-pH2 pH meter is built tough for on-site measurements of pH and temperature in semi-solid, viscous, and protein-containing media. It’s a reliable bit of kit for anyone needing accurate readings in demanding environments, from food production lines to industrial processes.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHaving to measure pH on the spot for something like a batch of cooling lubricant or a dairy product means you need a tool that can handle a bit of mess and still give you reliable readings without fuss.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eQuality control in the food industry (cheese, fruit, jellies, meat products)\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eCosmetics manufacturing (creams, oils, lotions)\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eMetalworking (water-mixed solid cooling lubricants)\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eDrinking water analysis (on-site checks)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis meter is purpose-built for accurate readings in semi-solid, viscous, and protein-containing media. This includes a wide range of foodstuffs, liquid and paste-like cosmetics, and industrial water-mixed solid cooling lubricants. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eSimultaneous Measurement:\u003c\/strong\u003e Integrated pH immersion tip and NTC temperature sensor allow for quick, combined pH and core temperature readings.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eDurable Sensor Design:\u003c\/strong\u003e Features a leakproof, maintenance-free gel electrolyte with annular clearance, making the pH sensor resistant to dirt and built for the long haul.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eFlexible Calibration:\u003c\/strong\u003e Supports 1, 2, or 3-point calibration to ensure accuracy, complemented by an automatic final value recognition function.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eRugged Protection:\u003c\/strong\u003e Comes with a TopSafe protective case, providing IP68 waterproofing and protection against impact. The case is also hygienic and dishwasher safe.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eClear Display:\u003c\/strong\u003e Easy-to-read LCD provides a 2-line display for both parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003epH Measuring Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0 to 14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eTemperature Measuring Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0 to +60 °C (Short-term to +80 °C max. 5 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e±0.4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWeight (with TopSafe)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e115 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eDimensions (LxWxH)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e197 x 33 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eIP68 (with TopSafe case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1 x CR2032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e80 h (Auto Off 10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Diameter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0 to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e-20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eTesto 206-pH2 pH\/temperature measuring instrument\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eGel storage cap\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eTopSafe protective case\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eBelt buckle\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eWall bracket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eBefore each use, clean the probe tip thoroughly with distilled water to remove any residues from previous measurements.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003ePerform a 1, 2, or 3-point calibration using fresh, certified pH buffer solutions (e.g., pH 4.01, 7.00) according to the job requirements.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eGently immerse the pH immersion tip into the semi-solid or viscous medium, ensuring the sensor is fully covered.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAllow the reading to stabilise; the automatic final value recognition will help confirm when it's ready to log.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAfter measurement, rinse the probe with distilled water and replace the gel storage cap to keep the sensor hydrated and ready for the next job.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eThe TopSafe case can be cleaned by hand or in a dishwasher to maintain hygiene, especially in food or cosmetic applications.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eNot designed for use with highly corrosive or extremely abrasive media that could damage the sensitive pH probe.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEnsure the pH probe tip is fully immersed in the sample for accurate and stable readings, particularly for temperature compensation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eRegular calibration with quality buffer solutions is critical to maintain measurement accuracy over time.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAlways adhere to good hygiene practices, especially when conducting measurements in food or pharmaceutical environments.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eThe specified short-term temperature limit of +80 °C should not be exceeded for more than five minutes to prevent sensor damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eKeep your buffer solutions fresh and calibrate regularly. A dodgy calibration is worse than no calibration, especially when food safety or industrial process control is on the line. Old buffer solutions give you false readings.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with Testo pH buffer solutions (like pH 4.01 and 7.00), a spare pH probe, and replacement CR2032 batteries to keep your measurements accurate and your workflow smooth.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What types of media can the Testo 206-pH2 measure?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This meter is designed for semi-solid media, including viscous and protein-containing foodstuffs like cheese, fruit, and jellies. It's also suitable for liquid\/paste-like materials, creams, oils, and water-mixed solid cooling lubricants.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is the Testo 206-pH2 waterproof and easy to clean?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, it comes with a TopSafe protective case that gives it an IP68 rating, making it completely waterproof and resistant to dirt. The case is also dishwasher safe for easy cleaning, crucial for hygienic applications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the measurement range for pH and temperature?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Testo 206-pH2 measures pH values from 0 to 14 pH with an accuracy of \u0026#177;0.02 pH. Temperature measurements range from 0 to +60 \u0026#176;C, with short-term use up to +80 \u0026#176;C (max 5 minutes), and an accuracy of \u0026#177;0.4 \u0026#176;C.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43799310139451,"sku":"0563 2062","price":789.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/testo-206-ph2-front-0563-2062-int-2000x1500_ce2c52c6-9224-4c2a-a581-301bf1d90750.jpg?v=1784272707","url":"https:\/\/www.hvacshop.com.au\/products\/testo-206-ph2-ph-and-temperature-meter-0563-2062","provider":"HVAC Supply Shop","version":"1.0","type":"link"}