{"product_id":"testo-176-p1-five-channel-pressure-temperature-rh-data-logger-0572-1767","title":"Testo 176 P1 Five-Channel Pressure, Temperature, and RH Data Logger","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThe Testo 176 P1 is a highly accurate five-channel data logger designed for comprehensive environmental monitoring. It meticulously records pressure, temperature, and relative humidity, making it an indispensable tool for critical applications.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eEquipped with a large, easy-to-read display, the 176 P1 provides real-time insights into your environmental conditions. Its robust design ensures reliable performance in demanding settings, from laboratories to clean rooms and hospital control areas.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWith internal pressure and external NTC sensor connections, this versatile logger offers detailed data acquisition, ensuring secure and accurate documentation of conditions over time. Data transfer is streamlined via USB or optional SD card, supported by free downloadable ComSoft software for analysis.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhy It Matters\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAccurate and reliable environmental data logging is crucial for maintaining compliance, ensuring product integrity, and validating research in sensitive environments. The Testo 176 P1 provides the precision and data security needed to prevent costly errors and ensure regulatory adherence, safeguarding your operations and results.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eTesto 176 P1 pressure, temperature, and humidity highly accurate measurement logger\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eCertificate of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eRecords up to five measurements simultaneously for comprehensive monitoring.\u003c\/li\u003e\n\u003cli\u003eLarge, easy-to-read display for instant checking of current readings and limit violations.\u003c\/li\u003e\n\u003cli\u003eWide temperature measurement range from -20 °C to +70 °C.\u003c\/li\u003e\n\u003cli\u003eAutomatic measuring data backup ensures data integrity even if batteries run out or are changed.\u003c\/li\u003e\n\u003cli\u003eIP54 protection class provides enhanced durability against dust and splashing water.\u003c\/li\u003e\n\u003cli\u003eProfessional software with Excel export function simplifies programming, data analysis, and reporting.\u003c\/li\u003e\n\u003cli\u003eCapable of CFR 21 Part 11 Compliancy for regulated industries.\u003c\/li\u003e\n\u003cli\u003eData is secured within the logger and can be password protected using ComSoft software.\u003c\/li\u003e\n\u003cli\u003eEasy-to-change battery for minimal downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eMonitoring and documentation of laboratory conditions, including research projects.\u003c\/li\u003e\n\u003cli\u003eEnvironmental control in clean rooms to maintain sterile or controlled atmospheres.\u003c\/li\u003e\n\u003cli\u003eAccurate condition logging in hospital control areas.\u003c\/li\u003e\n\u003cli\u003eValidation and documentation for enviro chambers.\u003c\/li\u003e\n\u003cli\u003eGeneral highly accurate pressure, temperature, and humidity monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eFor critical applications requiring absolute data integrity and regulatory compliance, always leverage the ComSoft software's password protection and consider the CFR 21 Part 11 compliant version. This ensures your logged data is tamper-proof and meets the most stringent industry standards.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eTemperature - NTC Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e-20 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eTemperature - NTC Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e±0.2 °C (−20 to +70 °C) ±1 Digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eTemperature - NTC Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eHumidity - Capacitive Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0 to 100 %rH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eHumidity - Capacitive Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003edependent on probe selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eHumidity - Capacitive Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.1 %rH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eAbsolute Pressure Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e600 to 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eAbsolute Pressure Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e±3 mbar (0 to +50 °C) ±1 Digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e\u003cstrong\u003eAbsolute Pressure Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eTesto Humidity \/ Temperature Probe 12mm (0572 6172)\u003c\/li\u003e\n\u003cli\u003eTesto USB Connection Cable (0449 0047)\u003c\/li\u003e\n\u003cli\u003eComSoft Professional 4 Software (0554 1704)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eEnsure the highest level of accuracy and data security for your environmental monitoring needs. Invest in the Testo 176 P1 data logger today and gain complete confidence in your critical measurements. Contact HVAC Shop for expert advice and competitive pricing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the maximum number of measurements the Testo 176 P1 can record simultaneously?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Testo 176 P1 is a five-channel data logger capable of recording up to five different measurements at the same time, including pressure, temperature, and relative humidity.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is data secured on the Testo 176 P1, and what happens during a power loss?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Data on the Testo 176 P1 is secured within the logger and can be password protected using the ComSoft software. The device also features automatic measuring data backup, ensuring that your data is safe even if the battery runs out or is changed.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can the Testo 176 P1 be used for applications requiring CFR 21 Part 11 compliance?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, the Testo 176 P1 is capable of CFR 21 Part 11 Compliancy, making it suitable for regulated industries that require stringent electronic record-keeping and electronic signature standards.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43530476257339,"sku":"0572 1767","price":1871.29,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/testo-176-p1-front-0572-1767-us-2000x1500_00a23964-cbf8-4366-9835-7e444b4afcc5.jpg?v=1779245502","url":"https:\/\/www.hvacshop.com.au\/products\/testo-176-p1-five-channel-pressure-temperature-rh-data-logger-0572-1767","provider":"HVAC Supply Shop","version":"1.0","type":"link"}