{"product_id":"seeley-24v-drain-valve-sy-solenoid-24v","title":"Seeley 24V Drain Valve","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Seeley 24V Drain Valve is a crucial replacement part for maintaining your evaporative cooler, helping techs and DIY owners keep units running efficiently. In the harsh Australian climate, regular draining prevents scale and mould buildup, ensuring your cooler delivers fresh, clean air without costly breakdowns.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eI've seen firsthand how a clogged or faulty drain valve can lead to water overflow and premature pump failure, especially on a hot summer day when you need your cooler working reliably.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC Technicians\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eEvaporative Cooler Service Teams\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eCompetent DIY Homeowners\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eRefrigeration Apprentices working on domestic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis 24V drain valve is designed for use with a range of Seeley evaporative cooler models, including:\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eBreezair:\u003c\/strong\u003e EXQ, EZQ, EXS, EXD, EZD, EXH, EZH, ES, EV, EX, EZ series\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eBraemar:\u003c\/strong\u003e BMQ, LCQ, LCS, LCB, BM series\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eCoolair:\u003c\/strong\u003e CVP, CPL, CPS, CPQ series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eGenuine Seeley part ensures reliable performance and a perfect fit.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eOperates on a standard 24V power supply, compatible with most modern evaporative cooler control systems.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eEssential for automated draining cycles, preventing stagnant water and minimising scale build-up in the cooler's tank.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eDirect replacement for faulty or worn-out drain valves, restoring proper water management to your system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eSeeley Part Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e105345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eHVAC Shop SKU\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eSY-SOLENOID\/24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e1 x Seeley 24V Drain Valve (PN 105345)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always ensure the evaporative cooler's power supply is isolated at the mains switch and confirm lockout before starting any work.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eDrain \u0026amp; Disconnect:\u003c\/strong\u003e Drain any remaining water from the cooler's tank and carefully disconnect the wiring and plumbing from the old drain valve, noting its orientation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eInstall New Valve:\u003c\/strong\u003e Mount the new Seeley 24V drain valve, ensuring all connections are secure and watertight. Follow the manufacturer's specific instructions for your cooler model.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eTest Operation:\u003c\/strong\u003e Restore power and initiate a drain cycle to verify the valve opens and closes correctly. Check all connections for any leaks immediately after installation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eFinal Check:\u003c\/strong\u003e Observe the cooler during normal operation to ensure proper water levels are maintained and the drain function activates as expected.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAlways isolate power before performing any maintenance or installation work on evaporative coolers.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eEnsure the cooler's control board provides 24V output for the drain valve; incompatible voltages can cause damage.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eOnly compatible with the specific Seeley evaporative cooler models listed above.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eFollow all Australian electrical and plumbing standards, and relevant Safe Work guidance during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen you're replacing the drain valve, take the extra five minutes to give the cooler's water tank a thorough clean. Getting rid of any sediment and algae now will prevent premature blockages and keep the system running sweeter for longer.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with new evaporative cooler filter pads and a quality tank cleaning solution for a complete annual maintenance service, ensuring your unit runs efficiently throughout the hot season.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What evaporative cooler models is this drain valve compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This Seeley 24V Drain Valve is designed for specific Breezair (EXQ, EZQ, EXS, EXD, EZD, EXH, EZH, ES, EV, EX, EZ), Braemar (BMQ, LCQ, LCS, LCB, BM), and Coolair (CVP, CPL, CPS, CPQ) evaporative cooler models.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What voltage does this drain valve operate on?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The drain valve operates on a 24-volt (24V) electrical supply. It's crucial to ensure your cooler's control system provides 24V to avoid damage to the component or the unit.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is included with this product and what is its Seeley part number?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"You receive one Seeley 24V Drain Valve. The official Seeley Part Number for this component is 105345, and the HVAC Shop SKU is SY-SOLENOID\/24V.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Seeley","offers":[{"title":"Default Title","offer_id":43714463727675,"sku":"SY-SOLENOID\/24V","price":50.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/349_SY105345-1_bb677fe8-5c83-4562-a5f0-f83e82756899.jpg?v=1782710697","url":"https:\/\/www.hvacshop.com.au\/products\/seeley-24v-drain-valve-sy-solenoid-24v","provider":"HVAC Supply Shop","version":"1.0","type":"link"}