{"product_id":"pipe-clamp-surface-probe-tc-type-k-0602-4592","title":"Pipe Clamp Surface Probe (TC Type K)","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThe Testo 0602 4592 Pipe Clamp Surface Probe is a Type K thermocouple designed for efficient surface temperature measurements on pipes. It allows for quick and easy attachment to pipes ranging from 0.2 to 2.5 inches in diameter.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis probe delivers an exceptionally fast 5-second response time thanks to its spring thermocouple strip. It accurately adapts to the measurement object's temperature, even on uneven surfaces, making it reliable for various HVAC applications.\u003c\/p\u003e\n\u003ch3 style=\"color: #333; border-left: 4px solid #007acc; padding-left: 12px; margin-top: 25px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e✓ Quick and easy attachment to pipes via clamping bracket.\u003c\/li\u003e\n\u003cli\u003e✓ Suitable for pipe diameters from 0.2 to 2.5 inches (5 mm to 65 mm).\u003c\/li\u003e\n\u003cli\u003e✓ TC Type K temperature probe with a 4-foot (1.2 m) cable.\u003c\/li\u003e\n\u003cli\u003e✓ Fast reaction time of 5 seconds for efficient measurements.\u003c\/li\u003e\n\u003cli\u003e✓ Spring thermocouple strip adapts to uneven surfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #333; border-left: 4px solid #007acc; padding-left: 12px; margin-top: 25px;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x TC Type K temperature probe with clamping bracket 0602 4592\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cstrong\u003eTradie Pro Tip:\u003c\/strong\u003e Use this probe for rapid diagnostic checks on refrigerant lines or hot water supply pipes. Its quick response time helps identify temperature anomalies efficiently.\n\u003c\/blockquote\u003e\n\u003ch3 style=\"color: #333; border-left: 4px solid #007acc; padding-left: 12px; margin-top: 25px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e-76 to 266 °F \/ -60 to +130 °C (briefly up to 536 °F \/ 280 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eClass 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eReaction Time\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e5 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e3 oz. \/ 82 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e6 in. \/ 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eDiameter Probe Shaft Tip\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.236 in. \/ 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e3.937 ft. \/ 1.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eFixed Cable\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProduct Colour\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eInterface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003ePlug thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333; border-left: 4px solid #007acc; padding-left: 12px; margin-top: 25px;\"\u003ePair With\u003c\/h3\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\nConsider pairing this probe with a compatible Testo Data Logger, a Testo Thermometer, or Data Logger Accessories.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\nEnhance your temperature measurement capabilities with this reliable pipe clamp surface probe. Explore our range of Testo instruments to complete your toolkit.\n\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What pipe diameters can this probe measure?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This pipe clamp probe is designed to measure surfaces on pipes with a diameter ranging from 0.2 to 2.5 inches (5 mm to 65 mm).\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the temperature measuring range of the 0602 4592 probe?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The probe has a measuring range of -76 to 266 \\u00b0F (-60 to +130 \\u00b0C), with capabilities for short-term measurements up to 536 \\u00b0F (280 \\u00b0C).\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How quickly does the 0602 4592 probe respond to temperature changes?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Testo 0602 4592 Pipe Clamp Surface Probe boasts an exceptionally quick response time of 5 seconds.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43545253412923,"sku":"0602 4592","price":451.65,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/0602-4592-probe-temperature-001483_373a578c-ccac-4c7a-90ca-3ed291d97c80.jpg?v=1779687200","url":"https:\/\/www.hvacshop.com.au\/products\/pipe-clamp-surface-probe-tc-type-k-0602-4592","provider":"HVAC Supply Shop","version":"1.0","type":"link"}