{"product_id":"hvac-system-pressure-sensor-ctsps5311275sp","title":"HVAC System Pressure Sensor","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis CTS Pressure Sensor, model CTSPS5311275SP, is a core component for monitoring refrigerant pressures within your HVAC or refrigeration system. It's built to provide accurate feedback, helping service techs keep an eye on system health and troubleshoot issues quickly. Keeping your sensors in good nick prevents major headaches down the line, especially during those scorching Australian summers when systems are working hardest.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eA faulty pressure sensor can lead to incorrect readings, causing a unit to cycle improperly, run inefficiently, or even trip out on high or low pressure. Swapping out a tired sensor with a reliable replacement like this one is a smart move for system longevity and efficiency.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eHVAC service and maintenance technicians\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eRefrigeration mechanics\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eApprentices learning system diagnostics\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eCompetent DIY owners replacing existing sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThe CTSPS5311275SP is designed as a direct replacement pressure sensor for a range of HVAC and refrigeration systems where the original sensor matches its electrical and physical specifications. It’s suitable for use with common refrigerants like R410A, R32, and R134a, provided the system pressures are within typical operating limits for this class of sensor. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eAccurate Pressure Monitoring:\u003c\/strong\u003e Provides reliable pressure readings crucial for system control and diagnostics.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Engineered to withstand typical HVAC operational environments and vibration.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eDirect Fit Replacement:\u003c\/strong\u003e Designed for easy installation, minimising downtime during service.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eBroad Refrigerant Compatibility:\u003c\/strong\u003e Suitable for modern refrigerants in common use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e1 x CTS HVAC System Pressure Sensor (CTSPS5311275SP)\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eBasic installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always disconnect and lock out power to the unit before commencing any work.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eRecover Refrigerant:\u003c\/strong\u003e If the sensor is connected to a live refrigerant circuit, recover all refrigerant from that section of the system using an ARCtick approved recovery unit.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eDepressurise \u0026amp; Remove:\u003c\/strong\u003e Once depressurised, carefully disconnect the old sensor. Be mindful of any residual oil or refrigerant.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eInstall New Sensor:\u003c\/strong\u003e Apply a thread sealant suitable for refrigerants (if not pre-applied) and gently thread the new CTSPS5311275SP sensor into place. Torque to manufacturer's specifications.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eEvacuate \u0026amp; Charge:\u003c\/strong\u003e Evacuate the relevant section of the system to a deep vacuum (e.g., 500 microns) and then recharge with the correct type and amount of refrigerant.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eTest Functionality:\u003c\/strong\u003e Restore power and test the system, verifying the new sensor provides accurate readings on your manifold gauges or system display.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eOnly use this sensor on compatible systems and refrigerants as per the manufacturer's specifications for the overall unit.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eWorking with refrigerants requires a current ARCtick licence in Australia. Always adhere to industry best practices.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEnsure proper system depressurisation before removing or installing, to prevent refrigerant release or injury.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAlways follow Australian standards and Safe Work guidance when performing HVAC maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen fitting any sensor, make sure the system is clean and free of debris. A bit of dirt in the port can throw off readings or even damage the new component. Double-check your connections for leaks before pressurising.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this pressure sensor with digital manifold gauges for accurate diagnostics and a quality vacuum pump to ensure proper system evacuation. Consider adding a set of flare nut wrenches for secure, leak-free connections.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bonaire","offers":[{"title":"Default Title","offer_id":43569062674491,"sku":"CTSPS5311275SP","price":964.82,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/Bonaire_Controller_Conversion_Kit_PNE_to_TYT_Tytronics_MB4_Star_Models_1000px_Product__89859.1574920528.jpg?v=1780545042","url":"https:\/\/www.hvacshop.com.au\/products\/hvac-system-pressure-sensor-ctsps5311275sp","provider":"HVAC Supply Shop","version":"1.0","type":"link"}