{"product_id":"hvac-pressure-sensor-ctsps5121225sp","title":"HVAC Pressure Sensor","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis HVAC Pressure Sensor (SKU: CTSPS5121225SP) is designed for accurate system monitoring, crucial for diagnosing issues and maintaining optimal performance in Australian conditions. Every tech knows that reliable pressure readings are the backbone of efficient troubleshooting and preventing costly system failures.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen your system is acting up, or you're dialling in a charge, a dependable pressure sensor like this helps you get the job done right, whether it’s a scorching summer day or a chilly winter morning.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service and maintenance teams\u003c\/li\u003e\n\u003cli\u003eRefrigeration apprentices learning system diagnostics\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners monitoring their own climate control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWithout specific manufacturer data, this pressure sensor (SKU: CTSPS5121225SP) is presented as a general replacement component. Typically, these sensors are found in a range of split systems, ducted units, and commercial refrigeration setups. We strongly recommend checking your existing sensor's specifications, connection type, and pressure range against this unit before purchase. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eDue to the nature of the provided product information, specific features for SKU: CTSPS5121225SP are not available. However, a typical HVAC pressure sensor often includes:\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAccurate pressure measurement for system protection and control\u003c\/li\u003e\n\u003cli\u003eDurable construction to withstand common refrigerants and oils\u003c\/li\u003e\n\u003cli\u003eStandard electrical connections for straightforward integration\u003c\/li\u003e\n\u003cli\u003eRobust design resistant to typical vibration and temperature fluctuations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eSpecific technical specifications for SKU: CTSPS5121225SP were not provided in the manufacturer's scraped data. For critical measurements like pressure range, electrical ratings, and connection thread types, please refer to your system's service manual or contact our technical support team for assistance.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x HVAC Pressure Sensor (CTSPS5121225SP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always ensure the system is de-energised and locked out before commencing work. Verify with a suitable voltage tester.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepressurise System:\u003c\/strong\u003e If the sensor is on a refrigerant line, safely recover refrigerant using an ARCtick-approved recovery unit until the line is at atmospheric pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove Old Sensor:\u003c\/strong\u003e Carefully disconnect any wiring, noting colours and terminal positions. Use appropriate tools to unthread the faulty sensor, paying attention to any sealants or O-rings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall New Sensor:\u003c\/strong\u003e Apply suitable thread sealant (if specified by the manufacturer) or ensure O-rings are correctly seated. Thread in the new sensor and reconnect wiring accurately as per the system diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak Check \u0026amp; Evacuate:\u003c\/strong\u003e For refrigerant systems, pressure test the affected section with dry nitrogen, thoroughly leak check all connections, then evacuate the section to a deep vacuum (e.g., 500 microns).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRe-commission:\u003c\/strong\u003e Recharge the system (if applicable), restore power, and verify the new sensor is providing accurate readings through the system's control panel or a diagnostic tool.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eRefrigerant circuit work requires a current ARCtick licence to comply with Australian regulations.\u003c\/li\u003e\n\u003cli\u003eAlways follow Australian standards and Safe Work guidance for all HVAC maintenance tasks.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor's pressure and temperature ratings are compatible with your specific application to avoid damage or inaccurate readings.\u003c\/li\u003e\n\u003cli\u003eOnly connect to electrical circuits with correct voltage and current protection; never bypass safety devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eBefore installing any new sensor, grab your multimeter and check the resistance or voltage output of the old sensor (if possible) and compare it to the new one if specs are available. It helps confirm you're replacing like-for-like and can quickly spot a dead-on-arrival part, saving you time later.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with a digital manifold gauge set and a quality vacuum pump for comprehensive system diagnostics. You might also check our range of Schrader valve tools and refrigerant hoses for easy pressure port access and safe handling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this pressure sensor compatible with all common refrigerants like R32 and R410A?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Specific refrigerant compatibility for SKU: CTSPS5121225SP is not provided. We recommend checking your system's documentation and comparing it with the sensor's specifications, once available, to ensure safe and effective use with your specific refrigerant.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What type of electrical and pressure connections does this sensor use?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Without detailed product data for SKU: CTSPS5121225SP, we cannot confirm specific connection types. Most HVAC pressure sensors use standard flare or NPT threads for pressure connections and common spade, Deutsch, or Packard connectors for electrical hook-ups. Always verify against your existing sensor.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How do I ensure this sensor will work with my specific system's pressure range?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"To ensure compatibility, you must identify the operating pressure range of your existing system and the specific sensor you are replacing. Compare these figures with the technical specifications of SKU: CTSPS5121225SP once they are available, or consult your system's service manual before purchasing.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Bonaire","offers":[{"title":"Default Title","offer_id":43569062608955,"sku":"CTSPS5121225SP","price":970.88,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/bonaire-brand-new-genuine-3-star-upgrade-kit-pne-tyt-5311265sp-500x338.jpg?v=1780544927","url":"https:\/\/www.hvacshop.com.au\/products\/hvac-pressure-sensor-ctsps5121225sp","provider":"HVAC Supply Shop","version":"1.0","type":"link"}