{"product_id":"honeywell-universal-intermittent-pilot-ignition-module-s8610u-hws8610k","title":"Honeywell Universal Intermittent Pilot Ignition Module S8610U","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThe Honeywell Universal Intermittent Pilot Ignition Module S8610U (HWS8610K) is your go-to replacement for a stack of older intermittent pilot controls. This module handles ignition sequencing, flame monitoring, and safety shutoff for central furnaces, residential boilers, and other heating appliances using an intermittent pilot system.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eOut on a job, having a universal module like this in the truck means you can sort out a breakdown quickly, without needing to track down a brand-specific part. It makes fault-finding and repairs a lot simpler when you're dealing with a range of different older systems.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC service technicians and installers\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eGas fitters working on residential or light commercial heating\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eMaintenance teams for property management\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eCompetent DIY owners replacing existing intermittent pilot modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis S8610U module is designed to replace over 400 intermittent pilot ignition modules from various manufacturers, including White-Rogers, Robertshaw, Johnson, and UTEC (HSC). It works with existing intermittent pilot burners and supports both Natural Gas (NG) and LPG systems. It's suitable for single rod or dual rod\/remote sense applications. The module also combines with Q345, Q3451, Q3452 ignition modules and Honeywell VR8204, VR8304 or VR8345M combination gas control valves. It's equivalent to Honeywell\/Resideo PN: S8610U, S8610U3009 and Brivis PN: 80008897, B008897. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eUniversal Replacement:\u003c\/strong\u003e Directly replaces a wide range of intermittent pilot ignition modules from multiple manufacturers, streamlining your spare parts inventory.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eIntegrated Safety Shutoff:\u003c\/strong\u003e Provides 100 percent pilot gas shutoff if the pilot fails to light, ensuring safety in heating appliances.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eRepeated Ignition Trial:\u003c\/strong\u003e If the pilot fails, the module features a 6-minute delay before repeating the trial for ignition, continuing until the appliance lights or the call for heat stops.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eDual Fuel Compatibility:\u003c\/strong\u003e Fully compatible with both Natural Gas (NG) and Liquefied Petroleum Gas (LPG) heating systems.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eVersatile Sensing:\u003c\/strong\u003e Works reliably in both single rod and dual rod\/remote sense flame sensing applications.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eSpark Cable Adapters:\u003c\/strong\u003e Includes necessary adapters to allow field replacement without needing to change existing spark cables, saving time on the job.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHoneywell Universal Intermittent Pilot Ignition Module (S8610U)\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eCross reference guide\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eInstallation instructions\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAssorted accessories for easy replacement\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eSpark cable adapters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eIsolate Power \u0026amp; Gas:\u003c\/strong\u003e Before starting any work, ensure power is isolated at the main switchboard and the gas supply is positively shut off and locked out. Verify zero energy state.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eIdentify Wiring:\u003c\/strong\u003e Carefully photograph or sketch the existing wiring connections on the old module. Use the supplied cross-reference and instructions for the specific application.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eRemove Old Module:\u003c\/strong\u003e Disconnect all wiring and remove the faulty ignition module. Handle wiring carefully to avoid damage.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eInstall New Module:\u003c\/strong\u003e Mount the Honeywell S8610U in the same location and position as the old unit. Use the spark cable adapters if needed for your existing setup.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eReconnect \u0026amp; Test:\u003c\/strong\u003e Reconnect all wiring as per your documentation. Restore gas and electrical power, then cycle the heating appliance to verify correct ignition, flame sensing, and safety shutoff operation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003ePost-Service Checks:\u003c\/strong\u003e After successful operation, perform a gas leak check around all fittings if a gas valve was disturbed. Check for proper flue operation and ensure correct air\/fuel mixture if adjustable.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eInstallation and servicing of gas appliances must be performed by a licenced gas fitter and qualified electrician in accordance with local regulations and Australian Standards.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAlways isolate electrical power and ensure gas supply is shut off before commencing any work on heating appliances.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis module is for intermittent pilot systems only; it is not suitable for direct spark ignition or hot surface ignition applications.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eEnsure correct grounding for reliable flame sensing. A poor ground can lead to nuisance lockouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen swapping out an old module, take an extra minute to clean the flame sensor rod with fine emery paper. A dirty sensor is a common cause of intermittent pilot issues, even with a new module. Good contact means reliable ignition.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with a suitable combination gas control valve, such as a Honeywell VR8204 or VR8304, and a multimeter for checking electrical continuity and voltage during installation. You might also find a digital manometer useful for checking gas pressures during commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592829894715,"sku":"HWS8610K","price":183.43,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/660_HWS8610K_1.png?v=1781134710","url":"https:\/\/www.hvacshop.com.au\/products\/honeywell-universal-intermittent-pilot-ignition-module-s8610u-hws8610k","provider":"HVAC Supply Shop","version":"1.0","type":"link"}