{"product_id":"flue-gas-probe-pre-filter-industrial-engines-0600-7556","title":"Flue Gas Probe with Pre-Filter for Industrial Engines","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Testo flue gas probe, SKU 0600 7556, is built tough for efficient flue gas measurements on stationary industrial engines, especially diesel. Its integrated pre-filter keeps diesel particulates from fouling your analyser, which is a lifesaver when you're on a dusty mine site or busy industrial yard. You can trust this probe to stand up to the heat, literally, with its all-metal construction.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eRunning a service call on a genset or a heavy-duty industrial setup often means high temperatures and dirty exhaust. This probe handles it, giving you reliable readings to keep those big rigs running clean and efficient.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAustralian HVAC techs, industrial mechanics, and power generation maintenance teams working with:\u003c\/li\u003e\n\u003cli\u003eFlue gas measurement on industrial engines\u003c\/li\u003e\n\u003cli\u003eFlue gas measurement on catalytic converters\u003c\/li\u003e\n\u003cli\u003eFlue gas measurement on other industrial installations with high overpressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eDesigned to work seamlessly with compatible Testo measuring instruments like the Testo 340 and Testo 350 series. Its robust design is particularly suited for diesel engines due to the integrated preliminary filter.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated preliminary filter:\u003c\/strong\u003e Permanently welded for protection from diesel particulates, essential for industrial diesel engine work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-metal construction:\u003c\/strong\u003e Prevents melting of the handle from radiated heat when working close to hot exhaust stacks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional particle filter:\u003c\/strong\u003e Located within the 4-metre hose, offering extra protection against contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh temperature rating:\u003c\/strong\u003e Withstands flue gas temperatures up to 1,000 °C, suitable for demanding industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh overpressure capability:\u003c\/strong\u003e Designed to operate effectively at probe tip pressures up to 100 mbar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable probe shaft:\u003c\/strong\u003e Allows for easy replacement if damaged or worn, extending the probe's lifespan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e670 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e335 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eHose Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Diameter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eProbe Shaft Tip Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e14 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMaximum Flue Gas Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1,000 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eMaximum Overpressure (probe tip)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eStainless steel probe shaft including preliminary filter (335 mm long)\u003c\/li\u003e\n\u003cli\u003e2-chamber sampling hose including particle filter (4 m long)\u003c\/li\u003e\n\u003cli\u003eProbe handle\u003c\/li\u003e\n\u003cli\u003e(Optional thermocouple and heat protection handle sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eConnect the flue gas probe to your compatible Testo analyser (e.g., Testo 340 or 350) ensuring all connections are secure and leak-free.\u003c\/li\u003e\n\u003cli\u003eCarefully insert the probe shaft into the flue gas duct or exhaust stack, making sure the preliminary filter and probe tip are positioned correctly for sampling.\u003c\/li\u003e\n\u003cli\u003eMonitor your analyser readings for temperature, particulates, and gas concentrations, keeping an eye on the probe's maximum temperature and pressure limits.\u003c\/li\u003e\n\u003cli\u003eAfter use, allow the probe to cool. Clean any visible residue from the shaft and inspect the filters for blockage or damage. Replace the particle filter in the hose as needed.\u003c\/li\u003e\n\u003cli\u003eStore the probe safely in a transport bag to protect it from knocks and contamination between jobs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways wear appropriate PPE, including heat-resistant gloves, when handling hot probes or working near exhaust systems.\u003c\/li\u003e\n\u003cli\u003eEnsure the probe is compatible with your specific Testo analyser model and the application's maximum temperature\/pressure before use.\u003c\/li\u003e\n\u003cli\u003eNot designed for continuous long-term monitoring at extreme conditions; check manufacturer guidelines for duty cycles.\u003c\/li\u003e\n\u003cli\u003eRegularly inspect and replace particle filters to maintain accurate readings and protect your analyser.\u003c\/li\u003e\n\u003cli\u003eAdhere to all local safety regulations and Safe Work Australia guidelines when performing industrial engine maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen you're pulling readings off industrial diesel, those particulates can foul up your gear quick. Make sure you regularly check and swap out the particle filter in the hose — it's cheap insurance against expensive analyser repairs.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with a Testo 340 or Testo 350 combustion analyser, and consider adding the optional thermocouple for exhaust gas temperature measurement and a transport bag for easy, protected transport.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this probe compatible with all Testo flue gas analysers?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This probe is specifically designed for use with compatible Testo measuring instruments, such as the Testo 340 and Testo 350 series combustion analysers. Always confirm compatibility with your analyser model before purchase to ensure proper function.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What are the maximum temperature and pressure ratings for this probe?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The probe is rated for flue gas temperatures up to 1,000 \\u00b0C, making it suitable for demanding industrial applications. It can also handle high overpressure at the probe tip, up to a maximum of 100 mbar.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the probe include a thermocouple for temperature measurement?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No, the thermocouple for exhaust gas temperature measurement is not included with this standard flue gas probe. It is available as an optional accessory (SKU 0600 8898) for those who require parallel temperature measurement capabilities.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Testo","offers":[{"title":"Default Title","offer_id":43761012899899,"sku":"0600 7556","price":3313.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/0600-7556-700x570.jpg?v=1783575320","url":"https:\/\/www.hvacshop.com.au\/products\/flue-gas-probe-pre-filter-industrial-engines-0600-7556","provider":"HVAC Supply Shop","version":"1.0","type":"link"}