{"product_id":"coolbreeze-neatrol-roof-unit-control-board-cbsp3005","title":"Coolbreeze Neatrol Roof Unit Control Board","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Coolbreeze Neatrol Roof Unit Board (CBSP3005) is your direct replacement for maintaining or repairing compatible Coolbreeze evaporative coolers. Keeping these units running smoothly is critical, especially when the Aussie heat starts to bite.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eGetting a rooftop evaporative cooler running right before an Australian summer hits means having the correct, reliable parts on hand. A faulty control board can sideline a unit fast, leaving your customers sweating.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC technicians performing evaporative cooler service and repair.\u003c\/li\u003e\n\u003cli\u003eMaintenance teams managing commercial or industrial evaporative systems.\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners replacing failed components in their own Coolbreeze Neatrol units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis PCB is specifically designed as a direct replacement for Coolbreeze Neatrol Roof Unit models. It matches the original equipment part number SP3005.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eGenuine replacement Printed Circuit Board (PCB) for Coolbreeze Neatrol units.\u003c\/li\u003e\n\u003cli\u003eEnsures full functionality for your evaporative cooler's control system.\u003c\/li\u003e\n\u003cli\u003eMatches CoolBreeze Part Number: SP3005 for precise fitment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1x Coolbreeze Neatrol Roof Unit Board (CBSP3005)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always begin by cutting power to the evaporative cooler at the main switchboard and apply lockout\/tagout procedures. Double-check with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess Board:\u003c\/strong\u003e Carefully remove the unit cover to expose the existing control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument Connections:\u003c\/strong\u003e Take clear photos or label all wiring connections to the old board before removal. This is crucial for correct reinstallation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove Old Board:\u003c\/strong\u003e Disconnect all wiring and mounting screws for the faulty PCB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall New Board:\u003c\/strong\u003e Mount the new CBSP3005 board securely and reconnect all wiring as documented.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Functionality:\u003c\/strong\u003e Restore power and carefully test all functions of the evaporative cooler, including fan speeds, pump operation, and drain cycles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eThis board is specifically for Coolbreeze Neatrol Roof Units with the SP3005 part number; verify compatibility before purchase.\u003c\/li\u003e\n\u003cli\u003eAlways ensure power is completely isolated and locked out before handling electrical components.\u003c\/li\u003e\n\u003cli\u003eInstallation should be carried out by a qualified technician or a competent person familiar with evaporative cooler systems and electrical safety.\u003c\/li\u003e\n\u003cli\u003eFollow all relevant Australian standards and Safe Work guidance for electrical installations and rooftop access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eBefore you even think about swapping a board, do your voltage checks at the terminals. Sometimes it's a wiring fault or a blown fuse, not the whole PCB. Save yourself a call-back by properly diagnosing first.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eConsider picking up replacement evaporative cooler pumps, float valves, or even a new Coolbreeze wall controller to cover all common service needs on a rooftop unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Coolbreeze models is the CBSP3005 board compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The CBSP3005 control board is designed as a direct replacement for Coolbreeze Neatrol Roof Unit evaporative coolers. Always cross-reference the part number (SP3005) with your existing board to ensure correct fitment.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What should I check before ordering this replacement PCB?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Before ordering, confirm that your existing control board matches the Coolbreeze Part Number SP3005. It's also wise to perform diagnostic checks to rule out other issues like faulty wiring, sensors, or power supply problems before replacing the board itself.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is ARCtick licensing required to install this board?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No, ARCtick licensing is not required for installing an evaporative cooler control board, as evaporative coolers do not contain refrigerants. However, you must have the necessary electrical qualifications or be a competent person to work safely with electrical components.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Coolbreeze","offers":[{"title":"Default Title","offer_id":43714463891515,"sku":"CBSP3005","price":196.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/415_CBSP3005_1W.png?v=1782710704","url":"https:\/\/www.hvacshop.com.au\/products\/coolbreeze-neatrol-roof-unit-control-board-cbsp3005","provider":"HVAC Supply Shop","version":"1.0","type":"link"}