{"product_id":"brivis-transformer-csx-1-75a-bs80024702","title":"Brivis Transformer CSX 1.75A","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Transformer (BS80024702) is a direct replacement for CSX gas heater models, essential for keeping control boards powered and systems running smoothly. It converts standard 240V mains power down to 24V, which is what your heater's control circuit needs.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eGetting the right transformer prevents costly call-backs and protects sensitive electronics, especially when the old one's been cooked by a power surge or just failed due to age. It’s a key component to get right.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service technicians\u003c\/li\u003e\n\u003cli\u003eLicensed gas fitters\u003c\/li\u003e\n\u003cli\u003eResidential heating maintenance teams\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners maintaining Brivis ducted gas heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Transformer is designed for use with Brivis CSX series gas heaters. It's a direct match for Brivis Part Number 80024702 and B024702.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eGenuine Brivis part (PN: 80024702, B024702) ensures a perfect fit and reliable function.\u003c\/li\u003e\n\u003cli\u003eConverts standard 240V AC input to 24V AC output for control circuits.\u003c\/li\u003e\n\u003cli\u003eRated for 1.75 Amps, matching original Brivis CSX specifications.\u003c\/li\u003e\n\u003cli\u003eDesigned for dependable operation in Brivis ducted gas heating systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e24V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e1.75 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBrivis Part Numbers\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e80024702, B024702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1x Brivis Transformer CSX 1.75A (BS80024702)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate mains power to the Brivis gas heater at the switchboard before beginning work. Follow lockout\/tagout procedures if applicable.\u003c\/li\u003e\n\u003cli\u003eAccess the control board area of the Brivis CSX heater, carefully removing any panels or covers.\u003c\/li\u003e\n\u003cli\u003eDisconnect the wiring from the old transformer, making clear notes or taking photos of connections if not obviously labelled.\u003c\/li\u003e\n\u003cli\u003eMount the new Brivis Transformer (BS80024702) securely in its designated position.\u003c\/li\u003e\n\u003cli\u003eConnect all wiring to the new transformer, double-checking 240V input and 24V output terminals for correct polarity and secure connections.\u003c\/li\u003e\n\u003cli\u003eRestore power to the heater and perform a full functional test of the system according to Brivis manufacturer guidelines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eOnly for use with compatible Brivis CSX gas heater models as specified.\u003c\/li\u003e\n\u003cli\u003eElectrical work should only be performed by a licensed electrician or a competent, qualified person in accordance with local regulations.\u003c\/li\u003e\n\u003cli\u003eAlways ensure power is isolated and confirmed dead using a suitable voltage tester before touching any wiring or components.\u003c\/li\u003e\n\u003cli\u003eRefer to the Brivis service manual for specific installation instructions and wiring diagrams for your particular heater model.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eBefore replacing a transformer, always check for external issues like loose wiring, shorts, or excessive heat that might have caused the original failure. A new transformer can burn out quickly if the underlying problem isn't fixed first.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with Brivis control boards, ignitors, and other genuine Brivis heating spares for reliable system maintenance and to keep your ducted gas heater running efficiently.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592835858491,"sku":"BS80024702","price":54.14,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/646_BS80024702_1.png?v=1781133816","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-transformer-csx-1-75a-bs80024702","provider":"HVAC Supply Shop","version":"1.0","type":"link"}