{"product_id":"brivis-star-pro-ducted-gas-heater-spark-ignitor-bs80021025","title":"Brivis Star Pro Ducted Gas Heater Spark Ignitor","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis spark ignitor (part BS80021025) is a direct replacement for Brivis Star Pro series ducted gas heaters, ensuring your unit starts reliably every time. A failing ignitor is a common call-out, especially on older units that have seen a few tough Australian winters.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen your heater clicks but doesn't light, often the ignitor is the first thing we check. Swapping out a worn one can get your customer's heating back online fast.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eHVAC service technicians maintaining Brivis ducted gas heaters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eApprentices learning fault diagnosis on ignition systems.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eCompetent DIY owners replacing parts on their Brivis Star Pro units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis spark ignitor is specifically designed for Brivis Star Pro Series ducted gas heaters. It's built to work with the 'old NG2 PCB boards' found in these systems. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eGenuine Brivis spare part for direct fit and reliable operation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEnsures consistent ignition in Brivis Star Pro ducted gas heaters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eCompatible with older NG2 PCB control boards.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eIdentical to Brivis part numbers 80021025 and B021025.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eOne Brivis Star Pro Spark Ignitor (Part BS80021025).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Always isolate electrical power to the unit at the main switchboard and ensure gas supply is turned off before commencing any work.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eAccess:\u003c\/strong\u003e Locate the ignitor within the burner assembly of the Brivis Star Pro heater. This may require removing panels.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eDisconnect:\u003c\/strong\u003e Carefully disconnect the old ignitor's wiring. Note its orientation for correct reinstallation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eRemove \u0026amp; Replace:\u003c\/strong\u003e Unmount the old ignitor and install the new BS80021025 unit, ensuring it's securely seated. Reconnect the wiring firmly.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eTest:\u003c\/strong\u003e Restore gas and power, then initiate a heating cycle. Observe for proper ignition and flame sensing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eThis part is for Brivis Star Pro Series heaters only.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eGas appliance work should only be performed by appropriately licensed and competent personnel in Australia.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAlways follow manufacturer's instructions and relevant Australian standards for gas appliance servicing.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEnsure proper electrical isolation and gas shut-off before attempting any replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cstrong\u003eTradie Pro Tip:\u003c\/strong\u003e Before assuming the ignitor is completely dead, always check the wiring for corrosion or loose connections, especially in damp roof spaces. Sometimes it's a simple fix, but a fresh ignitor is good insurance for reliable starts.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eConsider checking related components like Brivis control boards, gas valves, or pressure switches when servicing a ducted gas heater. These often go hand-in-hand with ignition system issues.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592830451771,"sku":"BS80021025","price":34.16,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/628_BS80021025_1.png?v=1781134994","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-star-pro-ducted-gas-heater-spark-ignitor-bs80021025","provider":"HVAC Supply Shop","version":"1.0","type":"link"}