{"product_id":"brivis-hx-series-gas-heater-igniter-flame-sensor-bs80021026","title":"Brivis HX Series Gas Heater Igniter Flame Sensor","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Igniter Flame Sensor (BS80021026) is the genuine replacement part for HX series gas ducted heaters, keeping those cold Australian winters at bay. A faulty igniter or sensor is one of the most common callouts we see for 'no heat' issues, especially after the unit has been sitting idle for months.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eSwapping this out can get your customer's heating back online quickly and reliably, preventing uncomfortable downtime.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC service technicians, licensed gasfitters, and competent home owners maintaining their Brivis HX series gas ducted heater.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis igniter flame sensor is specifically designed for Brivis HX series gas ducted heaters. It is a direct replacement for Brivis part numbers 80021026 and B021026. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eGenuine Brivis replacement part for guaranteed fit and performance.\u003c\/li\u003e\n\u003cli\u003eCombines igniter and flame sensor functions into one unit for simpler replacement.\u003c\/li\u003e\n\u003cli\u003eDesigned to restore reliable ignition and flame proving on Brivis HX series heaters.\u003c\/li\u003e\n\u003cli\u003eRobust construction suitable for the typical operating conditions of a ducted gas heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x Brivis HX Series Igniter Flame Sensor (BS80021026)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate power to the ducted heater at the main switchboard and follow lockout\/tagout procedures.\u003c\/li\u003e\n\u003cli\u003eShut off the gas supply to the appliance before commencing any work.\u003c\/li\u003e\n\u003cli\u003eCarefully disconnect the wiring from the old igniter\/sensor. Note its orientation and connection points.\u003c\/li\u003e\n\u003cli\u003eRemove the old igniter\/sensor and install the new unit, ensuring it's seated correctly and secured.\u003c\/li\u003e\n\u003cli\u003eReconnect wiring exactly as it was removed. Double-check all connections.\u003c\/li\u003e\n\u003cli\u003eRestore gas and power, then test the heater's ignition sequence and flame proving circuit thoroughly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eThis part is only for use with Brivis HX series gas ducted heaters as specified.\u003c\/li\u003e\n\u003cli\u003eInstallation and servicing of gas appliances must be performed by a licensed gasfitter in accordance with Australian standards.\u003c\/li\u003e\n\u003cli\u003eAlways follow manufacturer's installation instructions and local gas regulations.\u003c\/li\u003e\n\u003cli\u003eEnsure proper combustion analysis is performed after any ignition component replacement to confirm safe and efficient operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\"When you're swapping one of these out, take a clear photo of the wiring before you disconnect anything. It saves a lot of head-scratching trying to figure out which wire goes where, especially on a tight rooftop job or in a dark ceiling space.\"\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with a quality manometer for checking gas pressures and a digital multimeter for diagnosing electrical faults. You'll also find relevant Brivis control boards and gas valves in our gas heating spares range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592830582843,"sku":"BS80021026","price":24.79,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/629_BS80021026_1.png?v=1781135043","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-hx-series-gas-heater-igniter-flame-sensor-bs80021026","provider":"HVAC Supply Shop","version":"1.0","type":"link"}