{"product_id":"brivis-heater-pilot-hot-surface-ignitor-bs80012918","title":"Brivis Heater Pilot Hot Surface Ignitor","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Heater Pilot Hot Surface Ignitor (HSI) is a direct replacement part for Buffalo and Wombat gas heating models, helping Aussie techs quickly restore reliable ignition. When a gas heater's pilot struggles to light, especially during those frosty winter mornings, a faulty HSI is often the culprit, leading to service call-outs.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eI've seen plenty of these fail over time, usually from carbon buildup or simply aging out, causing intermittent firing or complete lockout. Swapping this out is a common fix.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAustralian HVAC service technicians\u003c\/li\u003e\n\u003cli\u003eLicensed gasfitters\u003c\/li\u003e\n\u003cli\u003eCompetent homeowners maintaining Brivis Buffalo \u0026amp; Wombat gas heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Pilot HSI is specifically designed for Brivis Buffalo and Brivis Wombat gas heater models. It replaces Brivis Part Number 80012918 (also known as B012918) and Honeywell Part Number Q3450C1169. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eGenuine Brivis replacement part for assured fit and function.\u003c\/li\u003e\n\u003cli\u003eProvides direct hot surface ignition for Brivis Buffalo and Wombat gas heaters.\u003c\/li\u003e\n\u003cli\u003eEquivalent to Honeywell Q3450C1169 and Brivis 80012918 \/ B012918.\u003c\/li\u003e\n\u003cli\u003eHelps restore reliable ignition, preventing heater lockout during colder months.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\u003cli\u003eOne (1) Brivis Heater Pilot Hot Surface Ignitor (HSI) for Buffalo \u0026amp; Wombat Models (BS80012918).\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eIsolate power and gas supply to the Brivis heater, following lockout\/tagout procedures before commencing any work.\u003c\/li\u003e\n\u003cli\u003eCarefully remove the access panel to locate the existing pilot HSI assembly within the heater.\u003c\/li\u003e\n\u003cli\u003eDisconnect the electrical leads and unmount the old ignitor from its position.\u003c\/li\u003e\n\u003cli\u003eInstall the new Brivis Pilot HSI, ensuring all electrical connections are secure and properly seated.\u003c\/li\u003e\n\u003cli\u003eRestore gas and power, then test the heater's ignition sequence multiple times to confirm proper operation and check for gas leaks with an approved detector.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eInstallation involves working with gas and electrical components; it must be performed by a licensed gasfitter or qualified HVAC technician.\u003c\/li\u003e\n\u003cli\u003eAlways isolate power and gas before attempting any repair or replacement on gas appliances.\u003c\/li\u003e\n\u003cli\u003eUse an approved leak detection solution on all gas connections after any installation where gas lines were disturbed.\u003c\/li\u003e\n\u003cli\u003eThis part is only compatible with Brivis Buffalo and Wombat models as specified.\u003c\/li\u003e\n\u003cli\u003eFollow all relevant Australian standards and Safe Work guidance for gas appliance servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eBefore you replace the HSI, give the old one a quick clean with a soft brush – sometimes carbon buildup is the issue, and you can save yourself a return trip if it's not actually failed yet. Always check the control board for fault codes too, as other issues can mimic an HSI fault.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with a digital manometer for checking gas pressures and an approved gas leak detector to ensure all connections are sound after service. You might also consider new Brivis control boards if the issue persists after replacing the HSI.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Brivis models is this HSI compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This Brivis Heater Pilot Hot Surface Ignitor (BS80012918) is specifically designed for Brivis Buffalo and Brivis Wombat gas heating models. It directly replaces Brivis Part Number 80012918 (B012918) and Honeywell Part Number Q3450C1169.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do I need a licence to install this part?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, working with gas appliances, especially replacing ignition components, requires a licensed gasfitter or qualified HVAC technician. Always ensure gas and power are isolated before starting work, and conduct thorough leak checks upon completion.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can I tell if my HSI is faulty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A faulty Hot Surface Ignitor often results in the heater attempting to ignite but failing, leading to a lockout or error code. You might hear the gas valve click but no ignition, or observe a very weak or no glow from the ignitor before the gas fails to light.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592834187323,"sku":"BS80012918","price":101.58,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/614_BS80012918_1.png?v=1781134619","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-heater-pilot-hot-surface-ignitor-bs80012918","provider":"HVAC Supply Shop","version":"1.0","type":"link"}