{"product_id":"brivis-gas-valve-earth-wiring-loom-hcca621-bs80023172","title":"Brivis Gas Valve Earth Wiring Loom HCCA621","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis earth wiring loom is a critical replacement part for your Brivis ducted gas heater's gas valve. It helps maintain the safe and reliable operation of the heating system, especially after servicing or if the original loom has seen better days.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAnyone who's spent a summer afternoon tracing electrical faults in a hot roof space knows the value of having the right, genuine loom on hand.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC techs, gasfitters, and competent DIY owners working on Brivis ducted gas heaters.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis wiring loom is specifically designed for Brivis ducted gas heaters that use the HCCA621 gas valve. It's an original Brivis part, P\/N: 80023172 (also referenced as B023172), ensuring a direct fit and reliable performance. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eDirect replacement for Brivis HCCA621 gas valve earth wiring looms.\u003c\/li\u003e\n\u003cli\u003eGenuine Brivis part (P\/N: 80023172, B023172) for guaranteed fit and function.\u003c\/li\u003e\n\u003cli\u003eEnsures correct earthing and electrical connection for the gas valve.\u003c\/li\u003e\n\u003cli\u003eHelps prevent potential electrical faults and promotes safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eOne (1) Brivis Earth Wiring Loom HCCA621 (P\/N: BS80023172 \/ B023172).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate power to the ducted gas heater at the main switchboard and perform lockout\/tagout procedures before commencing work.\u003c\/li\u003e\n\u003cli\u003eIdentify the existing earth wiring loom connected to the gas valve. Take photos if needed for reassembly.\u003c\/li\u003e\n\u003cli\u003eCarefully disconnect the old loom, noting its connection points.\u003c\/li\u003e\n\u003cli\u003eConnect the new Brivis Earth Wiring Loom HCCA621 (BS80023172) securely to the gas valve and the appropriate earth point as per the manufacturer's diagrams.\u003c\/li\u003e\n\u003cli\u003eDouble-check all connections for tightness and correct placement.\u003c\/li\u003e\n\u003cli\u003eRestore power and conduct a full operational check of the ducted heater, ensuring the gas valve functions correctly and safely.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eInstallation should only be performed by a licensed gasfitter or qualified HVAC technician.\u003c\/li\u003e\n\u003cli\u003eAlways ensure power is isolated before working on electrical components.\u003c\/li\u003e\n\u003cli\u003eUse only with compatible Brivis HCCA621 gas valves as specified.\u003c\/li\u003e\n\u003cli\u003eFollow all Australian standards and manufacturer's installation guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen replacing wiring looms, give all terminal connections a good clean. A bit of fine sandpaper or a wire brush can prevent future resistance issues, especially in older units where corrosion can build up. It’s a small step that makes a big difference for reliability.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with other genuine Brivis heating spares like ignitors and control boards, or grab a reliable multimeter from our Testo range to diagnose any electrical issues.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What specific Brivis models is this wiring loom compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This wiring loom is designed for Brivis ducted gas heaters that utilise the HCCA621 gas valve. It is a direct replacement for Brivis P\/N: 80023172 (B023172).\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this a genuine Brivis spare part?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, this is a genuine Brivis earth wiring loom with part number BS80023172, also referenced as B023172. Using genuine parts ensures proper fitment and performance for your ducted heater.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do I need a special license to install this part?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Installation of gas heater components, especially those related to gas valves, should ideally be carried out by a licensed gasfitter or qualified HVAC technician. This ensures safety and compliance with Australian regulations.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592832254011,"sku":"BS80023172","price":19.23,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/645_BS80023172_2.png?v=1781135853","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-gas-valve-earth-wiring-loom-hcca621-bs80023172","provider":"HVAC Supply Shop","version":"1.0","type":"link"}