{"product_id":"brivis-gas-heater-pilot-injector-046mm-ef15t-ng-tradie-pack-of-10-hw390686-14b","title":"Brivis Gas Heater Pilot Injector 0.46mm EF15T NG (Tradie Pack of 10)","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Gas Heater Pilot Injector Tradie Pack provides ten genuine 0.46mm EF15T Natural Gas (NG) injectors (Honeywell 390686-4), essential for keeping Brivis gas heaters running reliably through the Aussie winter. It's a lifesaver for busy HVAC techs, gas fitters, and maintenance teams needing to service multiple units or have spares on hand.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eNothing's worse than a pilot light dropping out on a cold winter's night, so having a pack of these genuine parts means you can get the heat back on fast without waiting for a reorder.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eLicensed Gas Fitters\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC Service \u0026amp; Maintenance Teams\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eBrivis Gas Heater Specialists\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis pilot injector pack is designed for Brivis gas heaters that utilise the 0.46mm EF15T Natural Gas (NG) Honeywell 390686-4 pilot injector. It's crucial for maintaining correct gas flow and ignition performance in compatible models. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eTradie Pack Quantity:\u003c\/strong\u003e Includes 10 individual pilot injectors, great for stocking the work van.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eGenuine Brivis\/Honeywell Part:\u003c\/strong\u003e Ensures direct fit and reliable performance.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003e0.46mm Orifice:\u003c\/strong\u003e Precisely sized for correct gas flow on specified Brivis heaters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eNatural Gas (NG) Specific:\u003c\/strong\u003e Optimised for natural gas systems.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eEF15T Type:\u003c\/strong\u003e Matches specific pilot assembly designs for easy replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eInjector Orifice Size\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.46mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eGas Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eNatural Gas (NG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eInjector Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eEF15T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eHoneywell 390686-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003ePack Quantity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e10 injectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWeight (Tradie Pack)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0.50 KGS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e10 x Brivis Gas Heater Injector Pilot (0.46mm, EF15T, Natural Gas, Honeywell 390686-4)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eIsolate Services:\u003c\/strong\u003e Always turn off and tag out the gas and electrical supply to the Brivis heater before starting any work.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eAccess Pilot Assembly:\u003c\/strong\u003e Refer to the Brivis heater's service manual to safely access the pilot assembly where the injector is located.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eRemove Old Injector:\u003c\/strong\u003e Carefully unthread and remove the existing pilot injector, noting its precise location and orientation.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eInstall New Injector:\u003c\/strong\u003e Thread the new 0.46mm NG injector into place, ensuring it's snug but not overtightened to avoid damaging threads.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eReassemble \u0026amp; Leak Check:\u003c\/strong\u003e Put the pilot assembly and heater panels back together. Conduct a thorough gas leak check using an approved leak detection solution.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eTest Operation:\u003c\/strong\u003e Restore gas and electrical supply. Test the heater's ignition sequence and verify a stable, clear blue pilot flame.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eLicensed Installation:\u003c\/strong\u003e All gas and electrical items must be installed by a currently licensed installer in accordance with Australian standards.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eNatural Gas Only:\u003c\/strong\u003e This injector is for Natural Gas (NG) systems only. Do not use with LPG or other gas types.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eMatch Specifications:\u003c\/strong\u003e Verify that the 0.46mm EF15T specification matches the requirements of the specific Brivis heater model you are servicing.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eManufacturer Guidelines:\u003c\/strong\u003e Always follow the specific installation and safety guidelines provided in the Brivis heater's service manual.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003ePost-Installation Checks:\u003c\/strong\u003e Conduct thorough gas leak detection and operational checks after any replacement of gas components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eKeep a few of these 0.46mm pilot injectors in your van. They're small, easy to misplace, and a common culprit for nuisance pilot outages. Swapping one out can save you a much bigger job and a repeat call-out.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with gas leak detection fluid, a quality set of spanners, and a full gas heater service kit for efficient and safe Brivis heater maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What type of gas is this pilot injector compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This pilot injector is designed specifically for Natural Gas (NG) systems. It is not suitable for use with LPG or other gas types.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the size of the injector orifice?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This pilot injector features a 0.46mm orifice. This precise sizing is critical for maintaining correct gas flow and ensuring proper flame characteristics in compatible Brivis gas heaters.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does installing this part require a licensed professional?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, in Australia, all gas components, including this pilot injector, must be installed by a currently licensed gas fitter or qualified technician to ensure safety and compliance with Australian standards.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592832679995,"sku":"HW390686-14B","price":15.18,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/Brivis_Gas_Heater_Injector_Pilot_0.46mm_EF15T_NG_Honeywell_390686-4_1000px_Tradie_Pack_main__62636.jpg?v=1781136002","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-gas-heater-pilot-injector-046mm-ef15t-ng-tradie-pack-of-10-hw390686-14b","provider":"HVAC Supply Shop","version":"1.0","type":"link"}