{"product_id":"brivis-gas-heater-flame-backup-sensor-500mm-bs80014886","title":"Brivis Gas Heater Flame Backup Sensor 500mm","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis flame backup sensor is an essential spare for maintaining the reliable operation of Brivis gas heaters, ensuring your system runs safely through the colder months. When a flame sensor starts playing up, you get nuisance lockouts, and that's the last thing you need on a cold morning call-out.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eSpecifically designed for Brivis MPS models, this 500mm sensor helps the control board confirm ignition and maintain the flame, preventing gas leaks and ensuring efficient heating.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC service technicians working on Brivis gas heaters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eApprentices learning gas appliance fault finding.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eCompetent DIY owners maintaining specific Brivis MPS gas heater models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis flame backup sensor is specifically engineered to suit Brivis MPS gas heater models. It matches Brivis Part Numbers 80014886 and B014886. The sensor has a 500mm lead length, which is crucial for proper routing and connection within the appliance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different Brivis model or a non-Brivis heater, always cross-reference part numbers and lead lengths before ordering to ensure a correct fit and safe operation.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Designed as a specific replacement for Brivis ignitor flame backup sensors in MPS models.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eOptimal Length:\u003c\/strong\u003e Features a 500mm lead for straightforward installation and correct positioning.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eCritical Safety Component:\u003c\/strong\u003e Ensures the heater's control system accurately detects flame presence, preventing hazardous unburnt gas release.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eGenuine Part Number Match:\u003c\/strong\u003e Corresponds to Brivis PNs 80014886 and B014886 for assured compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e1x Brivis Gas Heater Flame Backup Sensor (500mm lead)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Before starting any work, ensure the main power supply and gas supply to the Brivis heater are completely isolated and locked out.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eAccess \u0026amp; Remove:\u003c\/strong\u003e Carefully access the combustion chamber area of the Brivis MPS heater and locate the existing flame sensor. Disconnect its electrical lead and carefully unmount the sensor.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eInstall New Sensor:\u003c\/strong\u003e Mount the new 500mm flame backup sensor in the exact position of the old one, ensuring it's correctly aligned to detect the flame. Reconnect the electrical lead securely.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eTest System:\u003c\/strong\u003e Restore gas and power supplies. Run the heater through a full cycle, observing ignition and flame detection to confirm the new sensor is functioning correctly without nuisance lockouts.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eFinal Checks:\u003c\/strong\u003e Confirm all access panels are re-secured and conduct any required post-service safety checks according to manufacturer guidelines and Australian standards.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis part is specific to Brivis MPS gas heater models; it may not be compatible with other heater types or brands.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eInstallation and servicing of gas appliances must only be performed by a licensed gas fitter in accordance with AS\/NZS 5601 and local regulations.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAlways ensure both electrical and gas supplies are isolated before commencing any work on the appliance.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eRegular maintenance of gas heating systems, including flame sensors, is crucial for safe and efficient operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eBefore you swap out a sensor for a \"no-flame\" fault, give the old one a good clean with fine emery paper. Sometimes it's just carbon buildup stopping the micro-amp signal, not a failed sensor. Saves a trip to the supplier if you can clean it up.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this Brivis flame sensor with our range of Brivis Control Boards and Pressure Switches to keep your heating system fully stocked with essential spares. You might also find our Universal Spares category helpful for general maintenance items.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Brivis models is this flame sensor compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This flame backup sensor (BS80014886) is specifically designed for Brivis MPS gas heater models. It matches Brivis Part Numbers 80014886 and B014886.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the length of the lead on this sensor?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Brivis Flame Backup Sensor (BS80014886) features a 500mm lead length. This is important for ensuring proper routing and connection within the gas heater appliance.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is an ARCtick licence required to install this part?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No, an ARCtick licence is not required for installing this flame sensor as it does not involve refrigerant handling. However, installation and servicing of gas appliances must be performed by a licensed gas fitter in Australia.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592830320699,"sku":"BS80014886","price":23.78,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/620_BS80014886_1.png?v=1781134781","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-gas-heater-flame-backup-sensor-500mm-bs80014886","provider":"HVAC Supply Shop","version":"1.0","type":"link"}