{"product_id":"brivis-gas-ducted-heater-pressure-switch-bs80021376","title":"Brivis Gas Ducted Heater Pressure Switch 165Pa","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Gas Ducted Heater Pressure Switch (NS2-1072-03) is an essential safety component for your Brivis ducted gas heating system. It helps ensure correct airflow proving before burner ignition, keeping your unit running safely and efficiently.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAnyone who's wrestled with intermittent lockout errors on a cold winter's morning knows the importance of a reliable pressure switch in keeping the heat on.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service technicians\u003c\/li\u003e\n\u003cli\u003eGas plumbers\u003c\/li\u003e\n\u003cli\u003eAppliance repair specialists\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners maintaining Brivis ducted gas heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis pressure switch is specifically designed for Brivis gas ducted heaters, replacing part numbers 80021376 and B021376. It operates at 165Pa.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eGenuine Brivis part for assured fit and function.\u003c\/li\u003e\n\u003cli\u003eModel designation NS2-1072-03.\u003c\/li\u003e\n\u003cli\u003eOperating pressure of 165Pa.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for Brivis PN: 80021376 and B021376.\u003c\/li\u003e\n\u003cli\u003eCrucial safety component for gas heater operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003ePressure Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003ePressure Rating\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e165 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eNS2-1072-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBrivis Part No.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e80021376, B021376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\u003cli\u003eOne (1) Brivis Gas Ducted Heater Pressure Switch (NS2-1072-03, 165Pa)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate power to the ducted heater at the main switchboard before starting any work.\u003c\/li\u003e\n\u003cli\u003eCarefully disconnect the existing pressure switch, noting hose and electrical connections.\u003c\/li\u003e\n\u003cli\u003eMount the new Brivis pressure switch, ensuring secure hose and electrical connections are re-established.\u003c\/li\u003e\n\u003cli\u003eVerify all connections are tight and hoses are free from kinks or damage.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the heater's operation through a full cycle, monitoring for correct ignition and shutdown.\u003c\/li\u003e\n\u003cli\u003ePerform a combustion analysis to confirm safe and efficient operation if you have the appropriate equipment.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eInstallation and servicing of gas appliances must only be performed by a licensed gas fitter or qualified technician in Australia.\u003c\/li\u003e\n\u003cli\u003eEnsure the correct pressure switch model is used for your specific Brivis heater to avoid operational issues or safety hazards.\u003c\/li\u003e\n\u003cli\u003eAlways follow manufacturer's installation instructions and relevant Australian standards.\u003c\/li\u003e\n\u003cli\u003eThis component operates in a low-pressure air proving circuit. Do not apply high pressures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen replacing pressure switches, always check the connecting rubber hoses for cracks or blockages. A faulty hose can give you intermittent faults that look like a bad switch, causing call-backs.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with a digital manometer for accurate pressure readings and replacement gas valves from our Brivis Heating range when conducting gas appliance diagnostics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Brivis models is this pressure switch compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This pressure switch, model NS2-1072-03 (165Pa), is a direct replacement for Brivis part numbers 80021376 and B021376. It is designed for use in various Brivis gas ducted heaters that specify these part numbers.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the operating pressure of this switch?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Brivis Pressure Switch (BS80021376) is rated for an operating pressure of 165Pa. This ensures proper airflow proving in the combustion system of your ducted heater.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do I need a special licence to install this part?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, installation or servicing of gas appliances and their components in Australia must only be carried out by a licensed gas fitter or qualified technician. Incorrect installation can pose serious safety risks.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43592835268667,"sku":"BS80021376","price":48.07,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/641_BS80021376_1.png?v=1781134079","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-gas-ducted-heater-pressure-switch-bs80021376","provider":"HVAC Supply Shop","version":"1.0","type":"link"}