{"product_id":"brivis-evaporative-cooler-526-pcb-add-on-module-bsb023072","title":"Brivis Evaporative Cooler 526 PCB Add-on Module","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis 526 PCB Add-on Module (BSB023072) is a direct replacement part designed to keep your Brivis evaporative cooler running smoothly through the Aussie summer. It's a key component for managing the cooler's functions, ensuring reliable operation.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eA faulty module can cause all sorts of headaches on a hot day, so having the right spare on hand is crucial for quick repairs and getting that cool air flowing again.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis add-on module is best suited for HVAC service technicians, evaporative cooler installers, maintenance teams, and competent DIYers who maintain their own Brivis evaporative units.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis 526 PCB Add-on Module is specifically designed for Brivis evaporative units that require part number B023072. It is an exact match for the Brivis 526 series.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check your existing control board's part number and specifications before ordering to ensure it's the right fit.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eDirect replacement for Brivis Part Number B023072.\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for Brivis 526 series evaporative cooler units.\u003c\/li\u003e\n\u003cli\u003eEnsures the reliable and proper operation of your evaporative cooling system.\u003c\/li\u003e\n\u003cli\u003eAn essential component for the cooler's main control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eOne (1) Brivis Evaporative Add-on Module 526 (BSB023072)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate power to the evaporative cooler at the main switchboard before starting any work. Use proper lockout\/tagout procedures.\u003c\/li\u003e\n\u003cli\u003eAccess the existing control board area within the evaporative unit, usually located under the lid.\u003c\/li\u003e\n\u003cli\u003eCarefully disconnect all wiring from the old add-on module, making sure to note their positions. Taking a clear photo is always a good idea.\u003c\/li\u003e\n\u003cli\u003eRemove the faulty module and securely install the new Brivis 526 PCB Add-on Module (BSB023072).\u003c\/li\u003e\n\u003cli\u003eReconnect all wiring firmly, double-checking every connection before restoring power to the unit.\u003c\/li\u003e\n\u003cli\u003eTest the cooler's various functions (pump, fan speeds, drain cycle) to confirm the new module is operating correctly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate power before attempting any installation, repair, or maintenance on electrical components.\u003c\/li\u003e\n\u003cli\u003eThis module is designed for Brivis 526 series evaporative units only. It may not be compatible with other models or brands.\u003c\/li\u003e\n\u003cli\u003eEnsure correct wiring connections as per manufacturer's diagrams to prevent damage to the unit or the new module.\u003c\/li\u003e\n\u003cli\u003eFollow all Australian electrical safety standards and Safe Work guidance when performing electrical repairs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eBefore pulling out the old control module, snap a quick photo of all the wiring connections. It saves a lot of head-scratching when you're connecting up the new one, especially on an older unit where diagrams might be faded or hard to read.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with other Brivis evaporative cooler spare parts like float valves or fan motors, and general electrical tools such as a multimeter for troubleshooting and diagnostics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Brivis models is this add-on module compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The BSB023072 module is specifically designed for Brivis 526 series evaporative units. It serves as a direct replacement for Brivis part number B023072.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this Brivis module difficult to install?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Installation requires basic electrical competency and the ability to safely isolate power to the unit. Always consult the Brivis service manual for your specific evaporative cooler model and take photos of existing wiring before disconnecting.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does this add-on module control in a Brivis evaporative cooler?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This add-on module acts as a key component within the evaporative cooler's main control system. It helps manage various operational functions, ensuring the unit runs efficiently and reliably.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43691820023867,"sku":"BSB023072","price":185.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/313_B023072_1W_500x500_26d82f9e-44f3-49d8-9f6b-577154a1c132.png?v=1782103715","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-evaporative-cooler-526-pcb-add-on-module-bsb023072","provider":"HVAC Supply Shop","version":"1.0","type":"link"}