{"product_id":"brivis-electronic-control-box-tek467-bsb022970","title":"Brivis Electronic Control Box TEK467","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Electronic Control Box TEK467 (BSB022970) is the brain for your Brivis evaporative cooling unit, ensuring all functions from fan speed to water pump activation run smoothly. It's an essential replacement part for HVAC technicians and competent DIY owners looking to restore their cooler's operation without hassle.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen an evaporative cooler starts playing up in the middle of a hot Australian summer, often the control board is the first place to look. Getting a direct fit replacement like this one saves a lot of diagnostic time.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service technicians replacing faulty Brivis evaporative cooler control boards.\u003c\/li\u003e\n\u003cli\u003eInstallers needing to swap out a defective PCB during a new unit commission.\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners maintaining their own Brivis evaporative cooling systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Brivis Electronic Control Box TEK467 is a direct replacement for Brivis Part Number B022970 and is designed to suit various Brivis evaporative cooling units. If you're running a different model, confirm the part number on your existing board before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eDirect OEM replacement for Brivis Evaporative Cooling PCB TEK467.\u003c\/li\u003e\n\u003cli\u003eEnsures reliable control of all evaporative cooler functions.\u003c\/li\u003e\n\u003cli\u003eRestores full operational capability to compatible Brivis units.\u003c\/li\u003e\n\u003cli\u003eIdentical fit and function to the original Brivis PN B022970.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x Brivis Electronic Control Box TEK467 (BSB022970)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always ensure the main power supply to the evaporative cooling unit is isolated and locked out before commencing any work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess Control Box:\u003c\/strong\u003e Remove the unit's outer casing or access panel to expose the existing control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument Connections:\u003c\/strong\u003e Take clear photos of all wiring connections to the old board. This is crucial for correct reinstallation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect \u0026amp; Remove:\u003c\/strong\u003e Carefully disconnect all wiring harnesses and mounting screws, then remove the faulty TEK467 board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall New Board:\u003c\/strong\u003e Mount the new BSB022970 control box and reconnect all wiring precisely as documented. Double-check every connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Operation:\u003c\/strong\u003e Restore power to the unit and test all functions (fan speeds, pump, dump valve, wall controller communication) to confirm correct operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate and lock out power to the unit before attempting any service or installation.\u003c\/li\u003e\n\u003cli\u003eInstallation involves electrical work and should ideally be performed by a qualified HVAC technician or electrician.\u003c\/li\u003e\n\u003cli\u003eOnly compatible with specified Brivis evaporative cooling units. Verify the part number (B022970) against your existing board.\u003c\/li\u003e\n\u003cli\u003eFollow all manufacturer's instructions and local electrical safety standards during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eDon't skip that step of photographing your wiring before you disconnect anything. It's a lifesaver when you've got a dozen wires that all look similar. A minute with your phone saves an hour of troubleshooting.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with other Brivis evaporative cooling spares like Brivis Wall Controllers, Brivis Pumps, or Brivis Fan Motors if you're undertaking a wider service or repair of your evaporative cooler.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Brivis units does this control box suit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Brivis Electronic Control Box TEK467 (BSB022970) is a direct replacement for Brivis Part Number B022970. It is designed for use in various Brivis evaporative cooling units. Always cross-reference the part number on your existing board to ensure compatibility.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is professional installation required for the BSB022970 control box?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This control box involves electrical connections and should ideally be installed by a qualified HVAC technician or licensed electrician. Always ensure power to the unit is isolated and locked out before attempting any work to ensure safety.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is included when I purchase the Brivis Electronic Control Box TEK467?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"When you purchase this product, you receive one Brivis Electronic Control Box TEK467, identified by SKU BSB022970. No additional wiring harnesses, sensors, or mounting hardware are included unless explicitly stated.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Brivis","offers":[{"title":"Default Title","offer_id":43691819991099,"sku":"BSB022970","price":605.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/312_B022970_1W_500x500_53424629-2161-400c-bd35-34020ded5802.png?v=1782103712","url":"https:\/\/www.hvacshop.com.au\/products\/brivis-electronic-control-box-tek467-bsb022970","provider":"HVAC Supply Shop","version":"1.0","type":"link"}