{"product_id":"breezair-icon-control-box-cpmd-dd2-sy109930","title":"Breezair ICON Control Box CPMD DD2","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThe Breezair ICON Control Box CPMD DD2 (SY109930) is a direct replacement part engineered to get your Breezair evaporative cooler back up and running smoothly. When your old control box dies, often due to a power surge or just plain wear and tear from harsh Australian summers, this is the essential component you need.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIt's a frustrating job when an evaporative cooler's control board glitches, leaving you with no effective cooling on a scorching hot day. This replacement ensures reliable operation for your unit's fan, pump, and dump valve cycles.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eHVAC technicians and service teams working on evaporative coolers.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEvaporative cooler maintenance specialists.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eCompetent DIY homeowners maintaining their own Breezair systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis control box is designed specifically for Breezair EXH and EZH series evaporative cooler units. It's a direct fit and replacement for Seeley part number 109930. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eDirect replacement for the original ICON Control Box CPMD DD2.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEnsures proper operation of all evaporative cooler functions.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eManufactured to match original equipment specifications.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eEssential control component for EXH and EZH series Breezair units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003e1x Breezair ICON Control Box CPMD DD2 (SY109930)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAlways isolate power to the evaporative cooler at the main switchboard before starting any work. Apply lockout\/tagout procedures as necessary.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eCarefully disconnect all wiring from the old control box. Take photos or make a wiring diagram if you're unsure, to ensure correct re-connection.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eRemove the old control box and mount the new Breezair ICON Control Box CPMD DD2 (SY109930) securely in its place.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eReconnect all wiring according to your diagram or photos, ensuring secure and correct connections to all terminals.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eRestore power to the unit and test all functions of the evaporative cooler using the wall controller, checking fan speeds, pump operation, and dump cycles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAlways ensure power is isolated and locked out before attempting any electrical work on evaporative cooling units.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eThis control box is only for use with compatible Breezair EXH\/EZH units as specified.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eElectrical work on HVAC systems should only be performed by appropriately qualified and licensed personnel.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 10px;\"\u003eAlways follow the manufacturer's installation instructions and relevant Australian electrical safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eBefore replacing a control box, always double-check the wall controller and other wiring for obvious damage, corrosion, or loose connections. Sometimes the issue isn't the main board itself, which can save you a job and the cost of a new part.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with replacement filter pads and a new float valve to give your Breezair evaporative cooler a full service while you're working on it. You might also want to check out our range of universal evaporative cooler parts for other common repair items.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which Breezair models is this control box compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This Breezair ICON Control Box CPMD DD2 (SY109930) is specifically designed for EXH and EZH series evaporative cooler units. It serves as a direct replacement for Seeley part number 109930.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do I need an ARCtick licence to install this control box?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No, an ARCtick licence is not required for installing evaporative cooler control boxes as they do not involve working with refrigerant circuits. However, any electrical work should only be performed by appropriately qualified and licensed personnel.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What should I check if my Breezair cooler isn't working before replacing the control box?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Before replacing the control box, it's wise to check simpler components like the wall controller, wiring connections for looseness or corrosion, and ensure the cooler is receiving power. Issues such as a faulty float switch, fan motor, or water pump can sometimes mimic a control board problem.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Seeley","offers":[{"title":"Default Title","offer_id":43703500603451,"sku":"SY109930","price":982.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/355_SY109930.jpg?v=1782354359","url":"https:\/\/www.hvacshop.com.au\/products\/breezair-icon-control-box-cpmd-dd2-sy109930","provider":"HVAC Supply Shop","version":"1.0","type":"link"}