{"product_id":"braemar-white-rodgers-36g22-gas-control-valve-w01033","title":"Braemar White Rodgers 36G22 Gas Control Valve","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Braemar White Rodgers 36G22-210 Gas Control Valve is a direct replacement part designed to keep ducted gas heaters running safely and efficiently. If you're dealing with a faulty gas valve, getting the right replacement is crucial for system reliability and occupant safety, especially during those frosty Australian winter mornings.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eI've seen my share of calls where a sticky or failed gas valve meant no heat for the customer. Swapping one of these out correctly ensures consistent ignition and operation, saving you callback headaches and keeping homes warm.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service technicians replacing faulty gas valves in Braemar ducted heating systems.\u003c\/li\u003e\n\u003cli\u003eApprentices and experienced tradies undertaking gas heater maintenance and repair.\u003c\/li\u003e\n\u003cli\u003eOwners of Braemar ducted heaters requiring genuine replacement parts for qualified installers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis White Rodgers Gemini 36G22-210 gas control valve is specifically designed for use in various Braemar ducted gas heating systems. It's a direct replacement for the older 36G22-216 model and corresponds to Seeley Part Number 628363. Always cross-reference the model number on your existing valve to ensure a perfect fit.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eGenuine Braemar on\/off gas control valve for reliable performance.\u003c\/li\u003e\n\u003cli\u003eManufactured by White Rodgers as the Gemini 36G22-210 model.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for earlier 36G22-216 White Rodgers gas valves.\u003c\/li\u003e\n\u003cli\u003eAlso identified by Seeley Part Number 628363, ensuring broad compatibility within Braemar units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1x Braemar White Rodgers 36G22-210 Gas Control Valve (W01033)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power \u0026amp; Gas:\u003c\/strong\u003e Before starting, always switch off electrical power to the heater at the breaker and turn off the main gas supply valve. Lock out if possible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation \u0026amp; PPE:\u003c\/strong\u003e Ensure adequate ventilation in the work area. Wear appropriate personal protective equipment, including safety glasses and gloves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepressurise System:\u003c\/strong\u003e Carefully release any residual gas pressure in the line before disconnecting the old valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect \u0026amp; Remove:\u003c\/strong\u003e Disconnect all electrical connections and gas lines from the existing valve. Note their positions for reassembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall New Valve:\u003c\/strong\u003e Fit the new White Rodgers 36G22-210 valve, ensuring all connections are properly aligned and sealed using approved thread sealant suitable for gas. Torque connections to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak Check:\u003c\/strong\u003e After re-establishing gas supply, thoroughly check all connections for leaks using a suitable gas leak detection fluid or electronic sniffer before restoring electrical power and test firing the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Operation:\u003c\/strong\u003e Run through the heater's operating cycle to confirm the new valve functions correctly, ensuring proper ignition and flame sensing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eInstallation and servicing of gas appliances must only be carried out by a licensed gas fitter in accordance with Australian Standards and local regulations.\u003c\/li\u003e\n\u003cli\u003eAlways isolate both gas and electrical supplies before commencing any work on the heating unit.\u003c\/li\u003e\n\u003cli\u003eOnly use this valve for the specified Braemar models and compatible White Rodgers\/Seeley systems. Do not adapt for other applications.\u003c\/li\u003e\n\u003cli\u003eThoroughly leak check all gas connections after installation before operating the heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen you're putting in a new gas valve, don't skimp on the thread sealant. A quality gas-rated sealant applied correctly is your first line of defence against leaks. Always follow up with a proper leak test – it’s non-negotiable.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with an electronic gas leak detector, quality gas-rated thread sealant, and appropriate hand tools for a seamless installation. Consider checking out our range of Ducted Gas Heater Spares for other common replacement parts.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Braemar heater models is the White Rodgers 36G22-210 valve compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This valve is designed for various Braemar ducted gas heating systems. It's crucial to cross-reference the part number on your existing valve with the White Rodgers 36G22-210 or Seeley PN 628363 to ensure compatibility.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does this gas control valve replace older White Rodgers or Braemar parts?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, the White Rodgers 36G22-210 (W01033) is a direct replacement for the earlier 36G22-216 model. It also corresponds to Seeley Part Number 628363 for Braemar applications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is a special licence required to install this gas control valve?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, installation and servicing of any gas appliance, including this control valve, must be performed by a currently licensed gas fitter in Australia. This ensures compliance with all safety standards and regulations.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Braemar","offers":[{"title":"Default Title","offer_id":43608041685051,"sku":"W01033","price":250.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/704_W01033_1.png?v=1781160643","url":"https:\/\/www.hvacshop.com.au\/products\/braemar-white-rodgers-36g22-gas-control-valve-w01033","provider":"HVAC Supply Shop","version":"1.0","type":"link"}