{"product_id":"braemar-wall-furnace-thermocouple-st0270416","title":"Braemar Wall Furnace Thermocouple","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis genuine Braemar Wall Furnace Thermocouple is a critical safety component for your D45 and D55 models. It's designed to reliably sense the pilot flame, ensuring the gas valve shuts off safely if the flame isn't present, preventing dangerous gas build-ups.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen you're dealing with older units in the dead of winter, a faulty thermocouple can mean no heat at all. Having a direct replacement on hand means you can get the furnace back up and running fast, keeping your customers warm when it counts.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC technicians and gas fitters servicing Braemar wall furnaces.\u003c\/li\u003e\n\u003cli\u003eAppliance service teams conducting routine maintenance or repairs.\u003c\/li\u003e\n\u003cli\u003eCompetent homeowners maintaining their own Braemar D45\/D55 heating units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis thermocouple is specifically designed as a direct replacement for Braemar D45 and D55 wall furnace units. It matches the SIT 0270416 part number, ensuring a perfect fit and reliable operation with these specific models. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eGenuine Braemar component, guaranteeing proper fit and reliable operation with your unit.\u003c\/li\u003e\n\u003cli\u003eMeasures 600mm in length, suitable for specific Braemar D45 and D55 wall furnaces.\u003c\/li\u003e\n\u003cli\u003eEssential safety device for flame supervision, preventing gas flow if the pilot light fails.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for SIT Part Number 0270416.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e600mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCompatible Models\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBraemar D45, Braemar D55 Wall Furnaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eSIT 0270416\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x Braemar Wall Furnace Thermocouple (600mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate the gas supply and electrical power to the furnace before commencing any work.\u003c\/li\u003e\n\u003cli\u003eSafely access the pilot assembly and thermocouple connections inside the Braemar wall furnace.\u003c\/li\u003e\n\u003cli\u003eCarefully disconnect the old thermocouple, making note of its routing and how it's connected at both ends.\u003c\/li\u003e\n\u003cli\u003eInstall the new 600mm thermocouple, ensuring the tip is correctly positioned within the pilot flame path.\u003c\/li\u003e\n\u003cli\u003eReconnect all fittings securely, then restore gas and power to test for proper ignition and flame proving.\u003c\/li\u003e\n\u003cli\u003eConduct a thorough gas leak check at all disturbed connections using an approved leak detection solution.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eInstallation of gas appliance components requires appropriate licensing (e.g., gas fitter's licence) as per Australian regulations.\u003c\/li\u003e\n\u003cli\u003eThis thermocouple is designed specifically for Braemar D45 and D55 wall furnace models only.\u003c\/li\u003e\n\u003cli\u003eAlways follow the furnace manufacturer's installation instructions and local gas fitting codes.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation is maintained when working on or near gas appliances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eBefore pulling the old thermocouple out, take a photo of its routing and how it sits in the pilot flame. It'll save you a headache getting the new one seated perfectly and prevent nuisance lockouts.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with a reliable gas leak detector and general heating spares like ignitors or pilot assemblies to ensure a complete repair or service for your Braemar unit.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Braemar","offers":[{"title":"Default Title","offer_id":43679709823035,"sku":"ST0270416","price":47.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/673_ST0270416_1.png?v=1781838192","url":"https:\/\/www.hvacshop.com.au\/products\/braemar-wall-furnace-thermocouple-st0270416","provider":"HVAC Supply Shop","version":"1.0","type":"link"}