{"product_id":"braemar-lead-thermistor-th-te-tx-sy611136","title":"Braemar Lead Thermistor for TH\/TE\/TX Models","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Braemar Lead Thermistor (part number SY611136) is your direct replacement for maintaining accurate temperature readings in Braemar TH, TE, and TX evaporative cooling systems. A faulty thermistor can cause all sorts of headaches, from inaccurate set points to system shutdowns, especially when you need reliable cooling during a hot Australian summer.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eKeeping your evaporative cooler running efficiently means ensuring all components, especially the sensors, are doing their job right. This genuine Braemar part helps avoid those frustrating 'no cool' call-outs.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service technicians replacing faulty thermistors in Braemar evaporative coolers.\u003c\/li\u003e\n\u003cli\u003eMaintenance teams for residential and light commercial properties with Braemar units.\u003c\/li\u003e\n\u003cli\u003eCompetent DIY homeowners looking to restore their Braemar cooler's performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis thermistor lead is specifically designed for Braemar TH, TE, and TX model evaporative coolers. It's a genuine Braemar part (Seeley PN: 611136), ensuring a perfect fit and reliable operation with compatible systems. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Specifically manufactured as a genuine Braemar component.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Sensing:\u003c\/strong\u003e Designed to provide precise temperature readings to the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Specific:\u003c\/strong\u003e Compatible with Braemar TH, TE, and TX evaporative cooler models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Size:\u003c\/strong\u003e Features a 6mm sensor diameter for proper seating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eSY611136 (Seeley PN: 611136)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eSensor Diameter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCompatible Models\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBraemar TH, TE, TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eLead Thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1x Braemar Lead Thermistor (SY611136)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always ensure the evaporative cooler's power supply is completely isolated and locked out before commencing any work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess Control Box:\u003c\/strong\u003e Open the cooler's control box or access panel where the existing thermistor connects to the main board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote Connections:\u003c\/strong\u003e Take a photo or carefully note how the old thermistor is wired before disconnecting it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove Old Thermistor:\u003c\/strong\u003e Gently unclip or unscrew the faulty thermistor from its mounting point and disconnect its wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall New Thermistor:\u003c\/strong\u003e Connect the new Braemar SY611136 thermistor lead, ensuring wires are properly seated and secured, and then mount the sensor correctly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest System:\u003c\/strong\u003e Restore power and test the evaporative cooler's operation, monitoring temperature readings and fan\/pump cycles for correct functionality.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eEnsure power is isolated and locked out before any electrical work.\u003c\/li\u003e\n\u003cli\u003eOnly for use with specified Braemar TH, TE, and TX evaporative cooler models.\u003c\/li\u003e\n\u003cli\u003eFollow all manufacturer's installation guidelines and local electrical safety regulations.\u003c\/li\u003e\n\u003cli\u003eInspect wiring for damage before and after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eBefore replacing a thermistor, always check its resistance at room temperature against the manufacturer's chart if you can find it. Sometimes a connection issue looks like a faulty sensor, and you don't want to swap a good part.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this Braemar thermistor with a digital multimeter for diagnosing electrical faults, and consider checking our range of evaporative cooler pumps or control boards if other issues are present.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Braemar models is this thermistor compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This Braemar Lead Thermistor (SY611136) is specifically designed for Braemar TH, TE, and TX series evaporative cooling units. It's a genuine replacement part to ensure proper system function.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the physical size of the sensor on this thermistor lead?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The sensor itself on the Braemar SY611136 thermistor lead has a diameter of 6mm. This ensures it fits correctly into its designated mounting point within the cooler.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this an original Braemar part, or an aftermarket component?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This is a genuine Braemar component, also referred to by Seeley PN: 611136. Using genuine parts helps maintain the cooler's warranty and ensures optimal performance and reliability.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Braemar","offers":[{"title":"Default Title","offer_id":43660725125179,"sku":"SY611136","price":63.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/681_SY611136_1W.png?v=1781670443","url":"https:\/\/www.hvacshop.com.au\/products\/braemar-lead-thermistor-th-te-tx-sy611136","provider":"HVAC Supply Shop","version":"1.0","type":"link"}