{"product_id":"braemar-flame-condensing-sparker-retro-kit-sy651799","title":"Braemar Flame Condensing Flame Sparker Retro Kit","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Braemar Flame Condensing Flame Sparker Retro Kit (SY651799) is your go-to solution for servicing specific Braemar ducted gas heaters. It provides a full refresh for the ignition and flame sensing components, critical for reliable and safe operation, especially in the colder months when a heater lockout is the last thing anyone wants to deal with.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eDesigned specifically for condensing models, this kit ensures your heater maintains optimal performance and efficiency, preventing call-backs caused by intermittent ignition or flame detection faults. Having this kit on hand means you're prepared for common ignition issues on Braemar condensing units.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC technicians performing routine maintenance or repairs on Braemar ducted gas heaters.\u003c\/li\u003e\n\u003cli\u003eService teams addressing ignition issues in residential or light commercial settings.\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners replacing faulty spark ignitors or flame sensors in compatible Braemar units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis retro kit is engineered for specific Braemar condensing ducted gas heaters. It's a direct replacement for the sparker and flame sensor in the following models:\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eTQ5 Series\u003c\/li\u003e\n\u003cli\u003eTQS5 Series\u003c\/li\u003e\n\u003cli\u003eTQM6 Series\u003c\/li\u003e\n\u003cli\u003eTQS6 Series\u003c\/li\u003e\n\u003cli\u003eTQS7 Series\u003c\/li\u003e\n\u003cli\u003eTG Series\u003c\/li\u003e\n\u003cli\u003eTH5 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIt also supersedes previous part numbers 651810, 636665, and 622187, simplifying inventory for common repairs. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Designed as a complete retro kit for sparker and flame sensor assemblies in specified Braemar condensing gas heaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Reliability:\u003c\/strong\u003e Provides new ignition and flame sensing components to restore consistent and safe heater operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensing Unit Specific:\u003c\/strong\u003e Optimised for the unique requirements and operating conditions of Braemar's condensing ducted gas heaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupersedes Old Parts:\u003c\/strong\u003e Replaces multiple legacy part numbers, making it easier to stock the correct spare.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eElectrode Flame Sense Long\u003c\/li\u003e\n\u003cli\u003eElectrode Dual Probe Long\u003c\/li\u003e\n\u003cli\u003eBracket Mount Flame Sense DGH\u003c\/li\u003e\n\u003cli\u003eBracket Spark Dual Probe 2022\u003c\/li\u003e\n\u003cli\u003eBracket Standoff Sparker Lead\u003c\/li\u003e\n\u003cli\u003eGrommet M233 Silicone\u003c\/li\u003e\n\u003cli\u003eScrew 6G*1\/4 Ph Phlp ZP\u003c\/li\u003e\n\u003cli\u003eLeaflet - Sparker Retrofit 2020 (Installation Guide)\u003c\/li\u003e\n\u003cli\u003eLeaflet Flame\/Sparker Dual Retro (Installation Guide)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power \u0026amp; Gas:\u003c\/strong\u003e Before starting any work, ensure the heater's electrical supply is turned off at the main switchboard and the gas supply is shut off at the isolation valve. Verify with a multimeter for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess \u0026amp; Disconnect:\u003c\/strong\u003e Remove necessary panels to access the existing spark ignitor and flame sensor assembly. Carefully disconnect the wiring and gas line (if integrated) and unmount the old components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall New Components:\u003c\/strong\u003e Mount the new Electrode Flame Sense Long and Electrode Dual Probe Long using the provided brackets and screws. Ensure correct orientation and secure fitting to prevent vibration issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReconnect \u0026amp; Verify:\u003c\/strong\u003e Reconnect all electrical leads according to the wiring diagram in the included leaflets. Double-check all connections for tightness and proper routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak Test \u0026amp; Commission:\u003c\/strong\u003e Restore gas and electrical supply. Perform a gas leak test around any disturbed gas connections if applicable. Initiate the heater and observe several ignition cycles to ensure consistent spark and stable flame sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Flueing:\u003c\/strong\u003e After reassembly, verify that all flueing components are secure and free of obstructions, and that combustion air intake is clear.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eThis kit is specifically designed for the listed Braemar condensing heater models only. It is not suitable for non-condensing or other brand units.\u003c\/li\u003e\n\u003cli\u003eWork on gas appliances requires appropriate licensing and certification in Australia. Only licensed gas fitters and HVAC technicians should undertake installation and repair of gas heating systems.\u003c\/li\u003e\n\u003cli\u003eAlways follow manufacturer's installation instructions and relevant Australian Standards (e.g., AS\/NZS 5601.1 Gas Installations) and Safe Work guidance.\u003c\/li\u003e\n\u003cli\u003eEnsure proper electrical isolation and lockout procedures are followed before commencing any work to prevent accidental energisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen installing these, always take photos of the old setup before you pull it apart. Even with the leaflets, a visual reference of the wiring and bracket orientation can save you a headache and prevent incorrect reassembly, especially on a cold rooftop install.\u003c\/p\u003e\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this retro kit with a reliable digital manometer for accurate gas pressure checks and suitable HVAC Shop universal gas valves for comprehensive gas heating system maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which Braemar heater models is this retro kit compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This Braemar Flame Condensing Flame Sparker Retro Kit (SY651799) is specifically designed for Braemar TQ5, TQS5, TQM6, TQS6, TQS7, TG, and TH5 condensing ducted gas heaters. It directly replaces the sparker and flame sensor in these units.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What components are included in the SY651799 retro kit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The kit includes an Electrode Flame Sense Long, Electrode Dual Probe Long, various mounting brackets (Flame Sense DGH, Spark Dual Probe 2022, Standoff Sparker Lead), a silicone grommet, screws, and two installation leaflets. These provide everything needed for a full replacement.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is an ARCtick license required to install this kit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"While an ARCtick licence isn't specifically for gas appliances, anyone working on gas heaters in Australia must hold appropriate gas fitting licences and certifications. Always ensure work is performed by a qualified and licensed professional following Australian standards.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Braemar","offers":[{"title":"Default Title","offer_id":43660724207675,"sku":"SY651799","price":113.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/706_651799_1W_500x500_51a0285a-8248-436b-a263-f643f7073d39.png?v=1781670404","url":"https:\/\/www.hvacshop.com.au\/products\/braemar-flame-condensing-sparker-retro-kit-sy651799","provider":"HVAC Supply Shop","version":"1.0","type":"link"}