{"product_id":"braemar-combustion-fan-short-neck-sy620510","title":"Braemar Combustion Fan Short Neck","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Braemar Short Neck Combustion Fan is a direct replacement for specific TH3 and TH4 ducted gas heaters, ensuring your unit keeps burning cleanly and safely. Keeping the combustion air flowing correctly is crucial for efficiency and prevents lockout codes, especially during those frosty Australian winter mornings.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen a combustion fan starts to fail, you'll often hear it grinding, or the heater might short cycle. Getting the right part in fast means less downtime and a warm house for your customers.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service technicians replacing worn Braemar combustion fans.\u003c\/li\u003e\n\u003cli\u003eMaintenance teams for residential properties with Braemar ducted heaters.\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners maintaining their own Braemar TH3 or TH4 units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis short neck combustion fan (SY620510) is designed as a direct replacement for specific Braemar TH3 and TH4 star ducted gas heaters. It's suitable for units produced prior to the introduction of Braemar's later manufactured fans. Make sure to check your unit's serial number for a match:\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eFor Braemar TH3 units used pre Serial No. T10050225.\u003c\/li\u003e\n\u003cli\u003eFor Braemar TH4 units used pre Serial No. T10070292.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model or serial range, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eDirect OEM replacement for designated Braemar TH3 and TH4 units.\u003c\/li\u003e\n\u003cli\u003e\"Short neck\" design matches original specifications for correct airflow and fitment.\u003c\/li\u003e\n\u003cli\u003eFIME fan motor ensures reliable combustion air delivery.\u003c\/li\u003e\n\u003cli\u003eDesigned to screw or rivet directly to the flue plate within the heater chassis.\u003c\/li\u003e\n\u003cli\u003ePart number SY620510 (also known as Seeley PN: 620510) for easy identification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x Braemar Combustion Fan Short Neck (SY620510).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always begin by switching off the main power to the heater at the isolation switch or circuit breaker. Use proper lockout\/tagout procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess Fan:\u003c\/strong\u003e Open the heater's service panel and locate the existing combustion fan, typically connected to the flue system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect \u0026amp; Remove:\u003c\/strong\u003e Carefully disconnect the electrical wiring and any associated hoses. Unscrew or un-rivet the old fan from the flue plate. Note how it was mounted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall New Fan:\u003c\/strong\u003e Mount the new Braemar SY620510 fan to the flue plate using the appropriate screws or rivets. Ensure a tight, secure fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReconnect \u0026amp; Test:\u003c\/strong\u003e Reconnect all electrical wiring and hoses correctly. Restore power and conduct a full operational test, checking for proper ignition and exhaust.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck for Leaks:\u003c\/strong\u003e For gas appliances, it's always good practice to check for any gas leaks around connections using a gas leak detector or approved solution after reassembly, though this specific part is on the air side.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eThis fan is specifically for Braemar TH3 and TH4 units within the specified serial number ranges. Double-check compatibility before installation.\u003c\/li\u003e\n\u003cli\u003eInstallation of gas appliance parts should ideally be performed by a licenced gasfitter or qualified HVAC technician.\u003c\/li\u003e\n\u003cli\u003eAlways isolate electrical power to the appliance before commencing any work to prevent electrocution.\u003c\/li\u003e\n\u003cli\u003eEnsure all connections are secure and proper sealing is maintained around the fan and flue system.\u003c\/li\u003e\n\u003cli\u003eFollow Australian standards and manufacturer guidance for safe installation and operation of gas heating appliances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen you're swapping one of these, always give the flue system a quick visual check. Sometimes, a blocked or corroded flue can put extra strain on the fan, leading to premature failure. A quick clean can save a call-back.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with other Braemar Ducted Heater Spares or general Gas Appliance Tools for comprehensive heater maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What Braemar heater models is this fan compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"This Braemar Short Neck Combustion Fan (SY620510) is compatible with specific Braemar TH3 units used pre Serial No. T10050225 and TH4 units used pre Serial No. T10070292. It is a direct replacement for these earlier models.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can I verify if SY620510 is the correct part for my heater?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The most reliable way is to check your heater's model and serial number against the compatibility details provided. This fan is specifically designed for TH3 and TH4 units within the stated serial number ranges.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is professional installation required for this combustion fan?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"While a competent DIY owner might handle it, installation of gas appliance components is best performed by a licenced gasfitter or qualified HVAC technician. This ensures safety and proper operation according to Australian standards.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Braemar","offers":[{"title":"Default Title","offer_id":43608034836539,"sku":"SY620510","price":221.25,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/687_SY620510_1.png?v=1781160601","url":"https:\/\/www.hvacshop.com.au\/products\/braemar-combustion-fan-short-neck-sy620510","provider":"HVAC Supply Shop","version":"1.0","type":"link"}