{"product_id":"bonaire-wiring-loom-connection-cable-20m-ctsps6051619sp","title":"Bonaire Wiring Loom Connection Cable 20 Metre","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Bonaire wiring loom cable provides a solid, extended connection for your evaporative cooler or heating system's low voltage controls. At 20 metres long with a 4-pin connection, it’s designed to link up Bonaire Navigator controllers, giving you flexibility on those trickier installs where the wall controller isn't right next to the unit. We've all been there, needing that extra length to tidy up a long cable run and avoid splices.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIt's a genuine Bonaire part, ensuring compatibility and reliable performance, which is crucial for keeping your comfort systems running smoothly through Australian summers or chilly winters. No one wants to chase intermittent faults from a dodgy connection.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC service technicians replacing faulty wiring.\u003c\/li\u003e\n\u003cli\u003eInstallers needing extended reach for Bonaire wall controllers.\u003c\/li\u003e\n\u003cli\u003eMaintenance teams ensuring reliable control system communication.\u003c\/li\u003e\n\u003cli\u003eCompetent DIY owners maintaining Bonaire evaporative coolers or ducted heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis wiring loom is specifically designed for Bonaire systems. It features a 4-pin connection and is suited for use with Bonaire Navigator Controllers. Its low voltage rating makes it ideal for control circuit applications in Bonaire evaporative coolers and ducted gas heaters.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model or brand, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Length:\u003c\/strong\u003e Generous 20-metre cable provides flexibility for various installation layouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Application:\u003c\/strong\u003e Suited for control and communication circuits, typically found in thermostats and system controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-Pin Connection:\u003c\/strong\u003e Standardised connector for Bonaire Navigator Controller compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Bonaire Part:\u003c\/strong\u003e Ensures correct fit and reliable operation with Bonaire equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLV TEK 698 Designation:\u003c\/strong\u003e Identifies the specific cable type for accurate part replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e20 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e4-Pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eLow Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBonaire Navigator Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBonaire Part Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e6051619SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eLV TEK Designation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eLV TEK 698\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1x Bonaire Wiring Loom Connection Cable (20 metres, 4-pin)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always ensure the main power to the Bonaire unit is switched off at the circuit breaker and locked out before commencing any wiring work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentify Connection Points:\u003c\/strong\u003e Locate the low voltage communication ports on both the Bonaire unit (e.g., evaporative cooler or ducted heater) and the Navigator wall controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the Cable:\u003c\/strong\u003e Carefully run the 20-metre cable, ensuring it’s protected from damage, pinch points, and excessive heat. Use appropriate cable ties or conduit where necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Securely:\u003c\/strong\u003e Plug the 4-pin connectors firmly into their respective sockets on both ends. Double-check for proper seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Operation:\u003c\/strong\u003e Once connections are made and secured, restore power and test the full functionality of the Bonaire Navigator controller, ensuring all modes and settings operate as expected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument Work:\u003c\/strong\u003e Note the cable replacement in your service log or on the unit's maintenance sticker.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eThis cable is for low voltage control circuits only; do not connect to mains voltage.\u003c\/li\u003e\n\u003cli\u003eOnly compatible with Bonaire Navigator Controllers requiring a 4-pin low voltage connection.\u003c\/li\u003e\n\u003cli\u003eEnsure proper cable routing to prevent physical damage or exposure to extreme temperatures.\u003c\/li\u003e\n\u003cli\u003eElectrical work should always be performed by a licensed electrician or competent person following all Australian standards and Safe Work guidance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWhen pulling this long cable, always use a draw wire or fish tape in conduits. A bit of cable lubricant can save you a heap of grief and prevent insulation damage, especially on those hot days when the conduit is a bit tight.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair this wiring loom with a new Bonaire Wall Controller or a replacement Bonaire Control Board for a complete system overhaul. You might also find other Bonaire Spares useful for routine maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bonaire","offers":[{"title":"Default Title","offer_id":43573018099771,"sku":"CTSPS6051619SP","price":67.29,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/799_CTSPS6051619SP_1.png?v=1780639921","url":"https:\/\/www.hvacshop.com.au\/products\/bonaire-wiring-loom-connection-cable-20m-ctsps6051619sp","provider":"HVAC Supply Shop","version":"1.0","type":"link"}