{"product_id":"bonaire-vulcan-pressure-switch-130pa-ct-pswitch-130","title":"Bonaire Vulcan Pressure Switch 130Pa","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Bonaire Vulcan pressure switch is a crucial safety component for keeping ducted gas heaters running safely in Australian homes and businesses. It monitors the air pressure within the flue system, ensuring safe combustion and preventing hazards.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAs anyone who's chased down an intermittent fault knows, a dodgy pressure switch can lead to frustrating call-backs and wasted time, so having a reliable replacement on hand is smart.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eHVAC service technicians replacing faulty components.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eGas fitters performing repairs or routine maintenance on ducted gas heaters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eMaintenance teams managing commercial Bonaire heating systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Bonaire pressure switch is specifically designed for Bonaire MB3 and MB4 series ducted gas heaters. It carries the Bonaire part number 5431201SP and is set to operate at a nominal pressure of 130Pa.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eIf you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eSpecific Pressure Rating:\u003c\/strong\u003e Calibrated for 130Pa operation, ensuring correct system function for compatible units.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eDirect Fit:\u003c\/strong\u003e Designed as a direct replacement for Bonaire MB3 and MB4 ducted gas heaters.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eGenuine Bonaire Part:\u003c\/strong\u003e Ensures compatibility and reliable performance as per manufacturer specifications.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eEssential Safety Component:\u003c\/strong\u003e Plays a vital role in the safe operation of your heating system by monitoring flue gas pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e1x Bonaire Vulcan Pressure Switch 130Pa (CT-PSWITCH-130)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Always disconnect main power to the heater at the isolation switch or circuit breaker before commencing any work.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eAccess Switch:\u003c\/strong\u003e Locate and access the existing pressure switch within the heater cabinet, typically near the fan or flue system.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eDisconnect \u0026amp; Remove:\u003c\/strong\u003e Carefully disconnect the electrical wiring and pressure tubing from the old switch. Note their positions for correct reinstallation. Remove the old switch.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eInstall New Switch:\u003c\/strong\u003e Mount the new Bonaire 130Pa pressure switch in the same location and reconnect the pressure tubing and electrical wiring securely.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cstrong\u003eTest Operation:\u003c\/strong\u003e Restore power to the heater and perform a functional test, observing burner ignition and system operation. Ensure the heater cycles on and off correctly and that there are no error codes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eWork on gas appliances should only be performed by a licensed gas fitter in accordance with Australian standards.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis pressure switch is specifically for Bonaire MB3 and MB4 units; using it on incompatible systems may lead to incorrect operation or safety issues.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eAlways ensure power is isolated and locked out before working inside any heating appliance.\u003c\/li\u003e\n\u003cli style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eProper flue system operation is critical for the correct functioning of this switch; inspect flues for blockages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen troubleshooting a pressure switch fault, don't just replace it without checking the flue. A partially blocked flue, a failing combustion fan, or even a dirty burner can cause low pressure, making a good switch look faulty. Always investigate the root cause first.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with other essential Bonaire heating spares like control boards, ignitors and sensors, or gas valves to ensure you have everything needed for comprehensive heater maintenance or repair.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bonaire","offers":[{"title":"Default Title","offer_id":43573017280571,"sku":"CT-PSWITCH-130","price":49.18,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/562_CT-PSWITCH-130.png?v=1780640094","url":"https:\/\/www.hvacshop.com.au\/products\/bonaire-vulcan-pressure-switch-130pa-ct-pswitch-130","provider":"HVAC Supply Shop","version":"1.0","type":"link"}