{"product_id":"bonaire-2-0uf-square-p2-capacitor-ct0160190sp","title":"Bonaire 2.0UF Square P2 Capacitor for Vulcan Wall Furnaces","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Bonaire 2.0UF Square P2 Capacitor is a direct replacement part designed for Vulcan Wall Furnaces. It's crucial for getting your furnace's fan or motor spinning reliably, especially during those frosty Australian winter mornings. A failing capacitor is a common no-start call, and having the right spare on hand saves a lot of hassle on site.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eKeeping your Bonaire wall furnace running smoothly means having the right components. This capacitor ensures your unit operates as the manufacturer intended, providing consistent warmth when it's needed most.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eBest For\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eHVAC technicians and service teams maintaining Bonaire Vulcan Wall Furnaces.\u003c\/li\u003e\n\u003cli\u003eExperienced DIY homeowners replacing faulty furnace capacitors.\u003c\/li\u003e\n\u003cli\u003eApprentices learning about heating system component replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003eThis Bonaire 2.0UF SQ P2 Capacitor (PN: 0160190SP) is specifically designed for use with Bonaire Vulcan Wall Furnaces. If you're running a different model, check fittings and specs before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Bonaire Part:\u003c\/strong\u003e Ensures direct fitment and compatibility with original systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.0UF Capacitance:\u003c\/strong\u003e Provides the correct electrical rating for efficient motor start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSQ P2 Designation:\u003c\/strong\u003e Matches the specific form factor required for Vulcan Wall Furnaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e Designed to restore furnace functionality and maintain performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 16px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #007acc; border: 1px solid #e0e0e0; padding: 10px; text-align: left; background-color: #f5f5f5;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBonaire Square Capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e2.0UF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eDesignation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eSQ P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003eBonaire Part Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e0e0e0; padding: 10px;\"\u003e0160190SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003e1 x Bonaire 2.0UF Square P2 Capacitor (CT0160190SP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eUsing It on the Job\u003c\/h2\u003e\n\u003col style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways isolate power to the furnace at the main breaker and apply a lockout tagout. Confirm zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003eDischarge any existing capacitors using a properly insulated tool (e.g., screwdriver with insulated handle bridging terminals) to avoid a shock hazard.\u003c\/li\u003e\n\u003cli\u003eCarefully remove the old capacitor, noting wiring connections. Take a clear photo of the wiring setup before disconnecting.\u003c\/li\u003e\n\u003cli\u003eInstall the new Bonaire 2.0UF Square P2 Capacitor, ensuring all connections are secure and correctly matched to the original wiring.\u003c\/li\u003e\n\u003cli\u003eRestore power to the furnace and test its operation, checking for proper fan start-up and overall function.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eLimitations \u0026amp; Safety Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003e\n\u003cli\u003eAlways disconnect and lock out power before handling electrical components to prevent injury.\u003c\/li\u003e\n\u003cli\u003eCapacitors can store a dangerous electrical charge even after power is off; always discharge them safely.\u003c\/li\u003e\n\u003cli\u003eOnly for use with compatible Bonaire Vulcan Wall Furnaces as specified by the manufacturer.\u003c\/li\u003e\n\u003cli\u003eEnsure correct wiring based on the furnace's service manual to prevent damage or malfunction.\u003c\/li\u003e\n\u003cli\u003eFollow all relevant Australian electrical safety standards and Safe Work guidance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003eTradie Pro Tip\u003c\/h2\u003e\n\u003cblockquote style=\"border-left: 4px solid #007acc; background-color: #f9f9f9; font-style: italic; padding: 15px; margin: 20px 0;\"\u003eWhen replacing a capacitor, always check for signs of failure in the old unit like bulging or leaking. If the new one fails quickly, investigate the motor itself for excessive load or bearing issues to avoid repeat call-backs. It's often not just the cap.\u003c\/blockquote\u003e\n\u003ch2 style=\"color: #007acc; border-bottom: 2px solid #f0f0f0; padding-bottom: 8px; margin-top: 35px;\"\u003ePair With\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.6; margin-bottom: 20px;\"\u003ePair with other Bonaire Heating Spares, a quality multimeter for diagnostics, or a range of hand tools for electrical work to complete your repair kit.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bonaire","offers":[{"title":"Default Title","offer_id":43569062314043,"sku":"CT0160190SP","price":49.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0316\/7787\/4235\/files\/783_CT0160190SP_1.png?v=1780545268","url":"https:\/\/www.hvacshop.com.au\/products\/bonaire-2-0uf-square-p2-capacitor-ct0160190sp","provider":"HVAC Supply Shop","version":"1.0","type":"link"}